35kv Copper/XLPE/Awa/PVC 1X400mm2 Power Cable
Product Detail
Basic Info
Model No:YJV72
Toepassing: Ondergronds
Voltage: Laag-en middenspanning Kabel
Stroom: DC & AC
Isolatiemateriaal: XLPE
Schede Materiaal: PVC
Materiaal Vorm: Ronde Wire
Wire Core Material: Bare koperdraad
Certificaat: ISO , CCC , CE , VDE
Extra Informatie.
Handelsmerk:Yifang
Verpakking:Steel-Wooden Drum
Standaard:1x400mm2
Oorsprong:P. R. China
Gs-Code:8544601200
Beschrijving
5~46KV XLPE insulated power cable
1. Brief of Description
Cross-linked polyethylene insulated power cable not only has excellent electric, mechanical properties, but also has powerful resistance against chemical corrosion, heat aging and environmental stress. Its structure is simple. The long term operating temperature is 90oC. It is convenient to use and can be laid with no restriction of different level.
Our enterprise can produce both flame retardant and non-flame retardant series of XLPE power cable.
Our XLPE power cable can be produced according to your specifications, which are equivalent to IEC, DIN, BS and ASTM, and some indexes are superior to standards stated above.
The flame-retardant cable covers all kinds of low-smoke low-halogen, low-smoke halogen free and three classes of A, B, C.
We can design and manufacture special XLPE cable according to other standards required by the customers, such as Heavy section cut apart conductors, water-resistance, defend termites, defend mouse and so on.
2. Service conditions and operation parameters of cable
A) Max. conductor operating temperature: 90oC
B) Short circuit temperature: 250oC
C) Ambient temperature: 30oC
D) Soil temperature: 20oC
E) Depth of laying in direct: 0.8m
F) Thermal resistance of soil: 150oC.cm/W
G) Thermal resistance of ducts: 120oC.cm/W
3. Application and Main type
Type | Description | Main Application | |
Copper Conductor | Aluminum Conductor | ||
YJV Cu/XLPE/PVC |
YJLV Al/XLPE/PVC |
Copper or aluminum conductor XLPE insulated, Copper tape screen PVC sheathed power cable |
For laying indoor, tunnel, underground and cannel. Unable to bear external mechanical pulling force and pressure during laid. |
YJV Cu/XLPE/L(H)DPE |
YJLV Al/XLPE/L(H)DPE |
Copper or aluminum conductor XLPE insulated, Copper tape screen PE/LDPE/HDPE sheathed power cable |
|
YJE Cu/XLPE/LSOH |
YJLE Al/XLPE/LSOH |
Copper or aluminum conductor XLPE insulated, Copper tape screen LSOH sheathed power cable |
|
YJSV Cu/XLPE/CWS/PVC N2XS(SE)Y |
YJLSV Al/XLPE/CWS/PVC N2XS(SE)Y |
Copper or aluminum conductor XLPE insulated, Copper wire+ Copper tape screen PVC sheathed power cable |
For laying indoor, tunnel, underground and cannel. Unable to bear external mechanical pulling force and pressure during laid, fault current requires large. CWS(Copper wire screen) type: A: Fixed section B: Full/one third/one sixth/one eighth/one sixteenth neutral |
YJSY Cu/XLPE/CWS/L(M.H)DPE N2XS(SE)2Y |
YJLSY Al/XLPE/CWS/L(M.H)DPE N2XS(SE)2Y |
Copper or aluminum conductor XLPE insulated, Copper wire+ Copper tape screen PE/LDPE/HDPE sheathed power cable |
|
YJE Cu/XLPE/CWS/LSOH |
YJLE Al/XLPE/CWS/LSOH |
Copper or aluminum conductor XLPE Copper wire+ Copper tape screen LSOH sheathed power cable |
|
YJV22 Cu/XLPE/STA/PVC |
YJLV22 Al/XLPE/STA/PVC |
Copper or aluminum conductor XLPE insulated, Copper tape screen, steel tape armored, PVC sheathed power cable |
For laying indoor, tunnel, underground and cannel. Able to bear external mechanical forces, but unable to bear large pulling force. |
YJV23 Cu/XLPE/STA/L(M.H)PE |
YJLV23 Al/XLPE/STA/L(M.H)PE |
Copper or aluminum conductor XLPE insulated, Copper tape screen, steel tape armored, PE/LDPE/HDPE sheathed power cable |
|
WD-YJY23 Cu/XLPE/STA/LSOH |
WD-YJLY23 Al/XLPE/STA/LSOH |
Copper or aluminum conductor XLPE insulated, Copper tape screen, steel tape armored, PVC sheathed power cable |
|
YJSV22 Cu/XLPE/CWS/STA/PVC N2XSEBY |
YJLSV22 Al/XLPE/CWS/STA/PVC N2XSEBY |
Copper or aluminum conductor XLPE insulated, Copper wire+ Copper tape screen, steel tape armored, PVC sheathed power cable |
For laying indoor, tunnel, underground and cannel. Able to bear external mechanical forces, but unable to bear large pulling force. fault current requires large. CWS(Copper wire screen) type: A: Fixed section |
Type | Description | Main Application | |
Copper Conductor | Aluminum Conductor | ||
YJSV23 Cu/XLPE/CWS/STA L(M.H)PE N2XSEB2Y |
YJLSV23 Al/XLPE/CWS/STA L(M.H)PE NA2XSEB2Y |
Copper or aluminum conductor XLPE insulated, copper wire+ copper tape screen, steel tape armored, PE/LDPE/HDPE sheathed power cable | For laying indoor, tunnel, underground and canal. Able to bear external mechanical forces, but unable to bear large pulling force. fault current requires large. CWS(Copper wire screen) tape: Fixed section |
WD-YJSY23 Cu/XLPE/CWS/STA/LSOH |
WD-YJLSY23 Al/XLPE/CWS/STA/LSOH |
Copper or aluminum conductor XLPE insulated, copper wire+ copper tape screen, steel tape armored, LOSH sheathed power cable | |
YJV32 Cu/XLPE/SWA/PVC |
YJLV32 Al/XLPE/SWA/PVC |
Copper or aluminum conductor XLPE INSULATED, Copper tape screen, galvanized steel wire armored, PVC sheathed power cable. | For laying in shaft, water under ground and large difference of level, able to bear external mechanical pressure and moderate pulling force. |
YJV33 Cu/XLPE/SWA/L(M.H)PE |
YJLV33 Al/XLPE/SWA/L(M.H)PE |
Copper or aluminum conductor XLPE insulated, copper tape screen, galvanized steel wire armored, PE/LDPE/HDPE sheathed power cable | |
WD-YJY33 Cu/XLPE/SWA/LSOH |
WD-YJLY33 Al/XLPE/SWA/LSOH |
Copper or aluminum conductor XLPE insulated, copper tape screen, galvanized steel wire armored, LSOH sheathed power cable. | |
YJSV32 Cu/XLPE/CWS/SWA/PVC N2XSWRY |
YJLSV32 Al/XLPE/CWS/SWA/PVC NA2XSWRY |
Copper or aluminum conductor XLPE insulated, copper wire+ copper tape screen, galvanized steel wire armored, PVC sheathed power cable | For laying in shaft, water under ground and large differnce of level, able to bear extenal mechanical pressure and moderate pulling force. fault current requires large. CWS(Copper wire screen) tape: Fixed section |
YJSV33 Cu/XLPE/CWS/SWA/L(M.H)PE N2XSER2Y |
YJLSV33 Al/XLPE/CWS/SWA/L(M.H)PE NA2XSER2Y |
Copper or aluminum conductor XLPE insulated, copper wire+ copper tape screen, galvanized steel wire armored, PE/LDPE/HDPE sheathed power cable | |
WD-YJY33 Cu/XLPE/SWA/LSOH |
WD-YJLY33 Al/XLPE/SWA/LSOH |
Copper or aluminum conductor XLPE insulated, copper wire+ copper tape screen, galvanized steel wire armored, LSOH sheathed power cable |
4. Scope of voltage grade and core number and cross-section
a) National standard
Rated voltage(KV) | 3.6/6 | 6/6 | 6/10 | 8.7/10 | 8.7/15 | 12/15 | 12/20 | 18/20 | 18/30 | 21/35 | 26/35 | |
Core Number | 1 core, 3 core | |||||||||||
Cross-section mm2 |
1C | 25~800 | 35~800 | |||||||||
3C | 25~400 | 35~400 |
b) IEC/BS/DIN standard
Rated voltage(KV) | 3.6/6 | 6/6 | 6/10 | 8.7/10 | 8.7/15 | 12/15 | 12/20 | 18/20 | 18/30 | 21/35 | 26/35 | |
Core Number | 1 core, 3 core | |||||||||||
Cross-section mm2 |
1C | 25~800 | 35~800 | |||||||||
3C | 25~400 | 35~400 |
c) ASTM standard
Rated voltage(KV) | 5001-8000 | 8001-15000 | 15001-25000 | 25001-28000 | 28001-35000 | 35001-46000 | |
1 core, 3 core | |||||||
Cross-section mm2 |
1C |
6AWG~1600kcmil | 2AWG~1600kcmil | 1AWG~1600kcmil | 2AWG~1600kcmil | 1/0AWG~1600kcmil | |
3C |
6AWG~1600kcmil | 2AWG~1600kcmil | 1AWG~1600kcmil | 2AWG~1600kcmil | 4/0AWG~1600kcmil |
5. D.C Resistance of finished cable at 20oC per km is not more than following:
Nominal Cross-section mm2 |
25 | 35 | 50 | 70 | 95 | 120 | 150 | 185 | 240 | 300 | |
20oC DC Resistance Ω/km |
Cu | 0.727 | 0.524 | 0.387 | 0.268 | 0.193 | 0.153 | 0.124 | 0.0991 | 0.0754 | 0.0601 |
Al | 1.2 | 0.868 | 0.641 | 0.443 | 0.320 | 0.253 | 0.206 | 0.164 | 0.125 | 0.100 | |
Nominal Cross-section mm2 |
400 | 500 | 630 | 800 | 1000 | 1200 | 1400 | 1600 | 1800 | 2000 | |
20oC DC Resistance Ω/km |
Cu | 0.0470 | 0.0366 | 0.0283 | 0.0221 | 0.0176 | 0.0151 | 0.0123 | 0.0108 | 0.0096 | 0.0086 |
Al | 0.0778 | 0.0605 | 0.0469 | 0.0367 | 0.0291 | 0.0247 | 0.0202 | 0.0177 | 0.0157 | ||
Nominal Cross-section AWG |
6 | 5 | 4 | 3 | 2 | 1 | 1/0 | 2/0 | 3/0 | 4/0 | |
20oC DC Resistance Ω/km |
Cu | 1.3219 | 1.0453 | 0.8298 | 0.6594 | 0.5211 | 0.4149 | 0.3281 | 0.2605 | 0.2065 | 0.1640 |
Al | 2.1699 | 1.7167 | 1.3631 | 1.0802 | 0.8551 | 0.6783 | 0.5401 | 0.4276 | 0.3376 | 0.2688 | |
Nominal Cross-section MCM |
250 | 300 | 350 | 400 | 450 | 500 | 550 | 600 | 650 | 700 | |
20oC DC Resistance Ω/km |
Cu | 0.1386 | 0.1158 | 0.0991 | 0.0865 | 0.0772 | 0.0695 | 0.0630 | 0.0579 | 0.0534 | 0.0495 |
Al | 0.2273 | 0.1897 | 0.1623 | 0.1421 | 0.1263 | 0.1138 | 0.1032 | 0.0948 | 0.0874 | 0.0813 | |
Nominal Cross-section MCM |
750 | 800 | 900 | 1000 | 1100 | 1200 | 1300 | 1400 | 1500 | 1600 | |
20oC DC Resistance Ω/km |
Cu | 0.0463 | 0.0434 | 0.0386 | 0.0347 | 0.0316 | 0.0289 | 0.0237 | 0.0248 | 0.0231 | 0.0217 |
Al | 0.0759 | 0.0711 | 0.0630 | 0.0569 | 0.0518 | 0.0473 | 0.0437 | 0.0405 | 0.0379 | 0.0357 |
- Next: Concentric Neutral Cable Copper/Aluminum Conductor with Communication Core 2X8AWG
- Previous: Control Cable Fr-XLPE Insulated Copper Conductors 600V 10 AWG
Contact us
Soortgelijk of gerelateerd
- No related articles