Flexibele Koperen Xlpe-Isolatie Pvc-Buitenkabel Met Coating
Basic Info
Boven het hoofd ,
Ondergronds ,
Industrieel ,
Centrale ,
Telecommunicatie ,
Computer
CCC ,
CE ,
UL
Extra Informatie.
Beschrijving
Power Cable
Standards
Products can be manufactured according to GB standard, IEC standard, ASTM standard, BS standard and DIN and other standard and customers` specific requirements.
Specification
1. Conductors: copper or aluminum.
2. Both armored and non-armored type power cables are available.
3. Voltage rating: 0.6/1kV 3.6/6kV 6/10kV 8.7/15kV 26/35kV.
4. PVC or XLPE sheathed.
5. Number of cable cores: one core (Single core),two cores(Double cores),three cores, four cores (Four Equal-section-area cores or three equal-section area cores and one smaller section area neutral core), five cores (Five equal-area cores or three equal-section-area cores and two smaller section area neutral cores).
Characteristics of Cable
1.Max Long-time operating temperature of PVC insulated cable is 70°C,XLPE 90°C
2.Installing temperature of cable should not be less than 0°C
3.Max short-circuit temperature is:PVC not exceed 160°C,XLPE 250°C,Not more than5 Sec.
4.Permitting bending radius cable: Not less than 10 D times (D:external diameter of cable)
5.Perfect chemical stability, resistant against acids, alkali, grease and organic solvents, and flamer retardant.
Number of Cores & Nominal Cross-section Area
Number of Cores | 1 | 2 | 3 | 3+1 | 4 | 3+2 | 4+1 | 5 |
Section Area (mm2) | 4 – 500 | 2.5 – 500 | 2.5 – 300 | 4 – 300 | 2.5 – 300 | 2.5 -300 | 4 – 300 | 2.5 – 95 |
Installation:
1. The installation temperature should not over 20ºC, If the ambient temperature is lower than 0ºC, the cable should be preheated.
2. The bending radius of cable should not less than 8 times.
3. After installantion, the cable should with stand voltage test for 15min. 35kv D.C.
In air:
1. As the single core cable laying in parallel, the distance between the cable’s center is 2 times (for cables which cross section area of conductor ≤185mm2) and
90mm (for cables which cross sectional area of conductor≥240mm2)
2. Ambient temperature: 30ºC
3. Max. temperature of conductor: 70ºC
4. Rating factors of current rating for ambient temperature:
Air temperature | 20ºC | 25ºC | 35ºC | 40ºC | 45ºC |
Rating factors | 1.12 | 1.06 | 0.94 | 0.87 | 0.79 |
Direct in ground:
1. When the single core cables are installed separately, the distance between the cable’s center is 2 times of the cable diameter.
2. Ambient temperature: 25ºC.
3. Max. temperature of conductor: 70ºC.
4. Soil thermour resistivity: 1.0ºC. m/w.
5. Depth: 0.7m
6. Rating factors under different ambient temp.:
Air temperature | 15ºC | 20ºC | 30ºC | 35ºC |
Rating factors | 1.11 | 1.05 | 0.94 | 0.88 |
PVC Insulation Electric Cable
TYPE | Description of Cable |
Main Applications |
|
CU core | AL core | ||
VV | VLV | Copper/Aluminium core,PVC insulated,PVC sheathed power cable | Non-armoured PVC cable are suited for laying indoors,In cable trench,On cable racks and in pipes. Unable bear external pressures and tensions. |
VY | VLY | Copper/Aluminium core,PVC insulated,PE sheathed power cable | |
VV22 | VLV22 | Copper/Aluminium core,PVC insulated,steel tape armored,PVC sheathed power cable | Steel-tape armoured PVC cables are suited for vertical burial.Can bear moderate positive pressures,Unable bear tension forces. |
VV23 | VLV23 | Copper/Aluminium core,PVC insulated,steel tape armored,PE sheathed power cable | |
VV32 | VLV32 | Copper/Aluminium core,PVC insulated,thin steel wire armored,PVC sheathed power cable | Thin steel wire armoured PVC cables are used in case of great difference of levels or vertical installation and Can do vertical burial.Can bear moderate positive pressures and tension forces. |
VV33 | VLV33 | Copper/Aluminium core,PVC insulated,thin steel wire armored,PE sheathed power cable | |
VV42 | VLV42 | Copper/Aluminium core,PVC insulated,thick steel wire armored,PVC sheathed power cable | Thick steel wire armoured PVC cables are suited for vertical installation and can be laid water or sea-bottom.Can bear greater positive pressures and tension forces. |
VV43 | VLV43 | Copper/Aluminium core,PVC insulated,thick steel wire armored,PE sheathed power cable |
XLPE Insulated electric cable
Type | Description | Application | |
Cu Core | Al Core | ||
YJV ZR-YJV |
YJLV ZR-YJLV |
Cu(Al)Core, XLPE Insulated, PVC Sheathed Power Cable Cu(Al)Core, XLPE Insulated, PVC Sheathed flame- retardant Power Cable |
Can be laid in indoor, outdoor, tunnels, cable channels, reinforced concrete pipelines and loose soil. Cable should not bear outer mechanic force, but can bear a certain tractional force. |
YJV22 ZR-YJV22 |
YJLV22 ZR-YJLV22 |
Cu(Al)Core, XLPE Insulated, Steel Tape Armored and PVC Sheathed Power Cable Cu(Al)Core, XLPE Insulated, Steel Tape Armored and PVC Sheathed flame- retardant Power Cable |
Laid underground. Cable can bear outer mechanic force, but should not bear large tractional force. |
YJV32 ZR-YJV32 |
YJLV32 ZR-YJLV32 |
Cu(Al)Core, XLPE Insulated, Steel Wire Armored and PVC Sheathed Power Cable Cu(Al)Core, XLPE Insulated, Steel Wire Armored and PVC Sheathed flame- retardant Power Cable |
Laid in indoor, tunnels and mines. Cable can bear outer mechanic force and fairly large tractional force. |
YJV42 ZR-YJV42 |
YJLV42 ZR-YJLV42 |
Cu(Al)Core, XLPE Insulated, Steel Wire Armored and PVC Sheathed Power Cable Cu(Al)Core, XLPE Insulated, Steel Wire Armored and PVC Sheathed flame- retardant Power Cable |
Can be laid in vertical section, indoor, tunnels and mines. Cable can bear outer mechanic force and very large tractional force. |