Antenne bundelkabel ABC Aerial overhead kabel met ACSR Messenger Core
Basic Info
Ondergronds
CE ,
CCC ,
RoHS
Extra Informatie.
Beschrijving
ABC cable is suitable for transmitting line and distributing line of rated voltage 0.6/1KV and others.It is widely used at tall buildings,traveling development area and rural area or other place the cost of underground network is expensive.
Code Name
ABC
Rated Voltage (Uo/U)
0.6/1KV
Temperature Range
-15ºC-90ºC
—————————————————————————————————————————–
CONSTRUCTION
Conductor: Copper or Aluminium
Insulation: XLPE
Normally,ABC Cable(ABC Bundled Cable-Aerial Cable) do not use copper,because Aluminium Cost is high,most of our customers use aluminium.
—————————————————————————————————————————–
CABLE STANDARDS
Chinese National Standards, IEC,SANS 1418-1, SANS1418-2, ASTMB230, ASTMB231,ASTM B398,ASTM B399, NF C33-209 and etc. upon request.
—————————————————————————————————————————–
Aerial Bundle Conductor-ABC(South Africa Standard Sizes)-SANS 1418-1
Table 01 Aerial Bundled Cable-ABC-AS NZS 3506.1
1+1 Structure | ||||||||||
Phase Conductor | Neutral Conductor | Completed Cable | ||||||||
Section | Insulation Thickness | Minimum number of wires | Max. dc resistance at 20°C | Section | Insulation Thickness | Minimum number of wires | Max. dc resistance at 20°C | Minimum breaking load | Approx. Overall Diameter | Approx. Weight Of Cable |
mm2 | mm | No. | ohm/km | mm2 | mm | No. | ohm/km | KN | mm | Kg/km |
1×16 | 1.3 | 6 | 1.91 | 1×16 | 1.3 | 6 | 1.91 | 4.4 | 15.0 | 140 |
1×25 | 1.3 | 6 | 1.20 | 1×25 | 1.3 | 6 | 1.20 | 7.0 | 17.6 | 210 |
1×35 | 1.5 | 6 | 0.868 | 1×35 | 1.5 | 6 | 0.868 | 9.8 | 19.6 | 270 |
1×50 | 1.5 | 6 | 0.641 | 1×50 | 1.5 | 6 | 0.641 | 14.0 | 22.8 | 370 |
1×95 | 1.7 | 15 | 0.320 | 1×95 | 1.7 | 15 | 0.320 | 26.6 | 30.6 | 680 |
2+1 Structure | ||||||||||
Phase Conductor | Neutral Conductor | Completed Cable | ||||||||
Section | Insulation Thickness | Minimum number of wires | Max. dc resistance at 20°C | Section | Insulation Thickness | Minimum number of wires | Max. dc resistance at 20°C | Minimum breaking load | Approx. Overall Diameter | Approx. Weight Of Cable |
mm2 | mm | No. | ohm/km | mm2 | mm | No. | ohm/km | KN | mm | Kg/km |
2×25 | 1.3 | 6 | 1.20 | 1×25 | 1.3 | 6 | 1.20 | 10.5 | 19.0 | 310 |
2×35 | 1.3 | 6 | 0.868 | 1×35 | 1.3 | 6 | 0.868 | 14.7 | 21.1 | 410 |
2×50 | 1.5 | 6 | 0.641 | 1×50 | 1.5 | 6 | 0.641 | 21.0 | 24.6 | 550 |
3+1 Structure | ||||||||||
Phase Conductor | Neutral Conductor | Completed Cable | ||||||||
Section | Insulation Thickness | Minimum number of wires | Max. dc resistance at 20°C | Section | Insulation Thickness | Minimum number of wires | Max. dc resistance at 20°C | Minimum breaking load | Approx. Overall Diameter | Approx. Weight Of Cable |
3×16 | 1.3 | 6 | 1.91 | 1×16 | 1.3 | 6 | 1.91 | 8.8 | 18.1 | 290 |
3×25 | 1.3 | 6 | 1.20 | 1×25 | 1.3 | 6 | 1.20 | 14.0 | 21.2 | 410 |
3×35 | 1.3 | 6 | 0.868 | 1×35 | 1.3 | 6 | 0.868 | 19.6 | 23.7 | 550 |
3×50 | 1.5 | 6 | 0.641 | 1×50 | 1.5 | 6 | 0.641 | 28.0 | 27.5 | 740 |
3×70 | 1.5 | 12 | 0.443 | 1×70 | 1.5 | 12 | 0.443 | 39.2 | 31.9 | 1000 |
3×95 | 1.7 | 15 | 0.320 | 1×95 | 1.7 | 15 | 0.320 | 53.2 | 36.9 | 1370 |
3×120 | 1.7 | 15 | 0.253 | 1×120 | 1.7 | 15 | 0.253 | 67.2 | 40.6 | 1690 |
3×150 | 1.7 | 15 | 0.206 | 1×150 | 1.7 | 15 | 0.206 | 84.0 | 43.9 | 2020 |
Nominal csetion area(sqmm)
|
Conductor structure
|
Insulation material
|
Insulation Thickness(mm)
|
Approx. Overall Diameter(mm)
|
Approx. weight
(kg/km)
|
Packing meters per drum
|
||
Phase
(Compacted AL)
|
Neutral
(bare ACSR)
|
|||||||
(No./mm)
|
Aluminum
(No./mm)
|
Steel
(No./mm)
|
||||||
1×16+16
|
7/1.72
|
6/1.72
|
1/1.72
|
XLPE
|
1.2
|
12.5
|
121.9
|
250-4000m
|
1×25+25
|
7/2.15
|
6/2.15
|
1/2.15
|
1.2
|
14.9
|
182.2
|
250-4000
|
|
1×35+35
|
7/2.54
|
6/2.54
|
1/2.54
|
1.4
|
17.5
|
254.7
|
250-3500m
|
|
1×70+70
|
19/2.15
|
12/2.15
|
7/2.15
|
1.4
|
23.6
|
382.2
|
250-3000m
|
|
1×95+95
|
19/2.54
|
12/2.54
|
7/2.54
|
1.6
|
27.6
|
528.2
|
250-3000m
|
|
2×16+16
|
7/1.72
|
6/1.72
|
1/1.72
|
1.2
|
14.2
|
187.6
|
250-4000m
|
|
2×25+25
|
7/2.15
|
6/2.15
|
1/2.15
|
1.2
|
16.7
|
273.8
|
250-3500m
|
|
2×35+35
|
7/2.54
|
6/2.54
|
1/2.54
|
1.4
|
19.7
|
386.9
|
250-3500m
|
|
2×70+70
|
19/2.15
|
12/2.15
|
7/2.15
|
1.4
|
26.1
|
617.2
|
250-3000m
|
|
2×95+95
|
19/2.54
|
12/2.54
|
7/2.54
|
1.6
|
30.5
|
850.9
|
250-3500m
|
|
3×70+70
|
19/2.15
|
12/2.15
|
7/2.15
|
1.4
|
29.7
|
1024.3
|
250-3000m
|
|
3×95+95
|
19/2.54
|
12/2.54
|
7/2.54
|
1.6
|
34.6
|
1413.7
|
250-3000m
|
- Next: Aluminium Alloy Conductor Aluminium Clad Invar Reinforced Aacsr Conductor
- Previous: Bare Conductor Cable Aluminum Conductor Alloy Reinforced Acar