Copper Core Steel Wire Armoured Power Cable

 Copper Core Steel Wire Armoured Power Cable

Product Detail

Basic Info

Model No:SWA
Toepassing: Bouw , Ondergronds
Voltage: Laag-en middenspanning Kabel
Stroom: DC-kabel
Isolatiemateriaal: XLPE
Certificaat: ISO , CE

Extra Informatie.

Handelsmerk:Jiapu
Verpakking:Wooden Drum or Wooden&Steel Drum
Standaard:IEC ASTM BS DIN, Any standard
Oorsprong:Henan, China
Gs-Code:8544492100
Productiecapaciteit:5000km/Month

Beschrijving

Copper Core Steel Wire Armoured Power Cable

Application:
Media Voltage XLPE Insulated power cable is used to transmit and distribute power in power transmission and distribution system of 35kV or lower. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable.

Property:

1.The highest allowed operating temperature of conductor for long-term working is 90 degrees.

2.In short circuit (Max long term is no more than 5 seconds). The highest temperature for conductor is no more than 250 degrees.

3.The cable is laid without horizontal drop limit. The environment temperature should be no lower than 0 when lay. Otherwise it should be preheated.

4.Excellent electrical performance, resistance to chemical corrosion.

5.They can stand advisable traction when laid.They can stand traction from Outside.Left low smoke halogen-free after burned.Retard the burning of the cable.

Specification:

IEC60502,designing and manufacturing special power cable according to the other standards required by the customers.

1)3.6/6(7.2)kV,3.6/6.6(7.2)kV,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable

No.X Nominal Cross Section of Conductor

Nominal Diameter of Conductor

Nominal Thickness of Insulation

Nominal Thickness of Copper Tape Screen

Nominal Thickness of Inner Sheath

Nominal Thickness of Steel Tape Armouring

Nominal Thickness of PVC Sheath

Approx. Overall Diameter

Approx. Weight

Al Conductor

Cu Conductor

No. X mm2

mm

mm

mm

mm

mm

mm

mm

kg/m

kg/m

3 X 25

6.0

2.5

0.1

1.2

0.2

1.9

37.9

1.87

2.32

3 X 35

6.9

2.5

0.1

1.3

0.5

2.0

41.5

2.10

2.73

3 X50

8.2

2.5

0.1

1.3

0.5

2.0

44.3

2.37

3.22

3 X 70

9.7

2.5

0.1

1.4

0.5

2.1

47.9

2.77

4.00

3 X 95

11.3

2.5

0.1

1.4

0.5

2.2

51.6

3.21

4.91

3 X 120

12.8

2.5

0.1

1.5

0.5

2.4

55.4

3.69

5.84

3 X 150

14.2

2.5

0.1

1.5

0.5

2.5

58.6

4.15

6.85

3 X 185

15.9

2.5

0.1

1.5

0.5

2.6

62.5

4.73

8.11

3 X 240

18.3

2.6

0.1

1.6

0.5

2.7

68.5

5.62

10.05

3 X 300

20.4

2.8

0.1

1.7

0.5

2.9

74.5

6.55

12.11

3 X 400

23.2

3.0

0.1

1.9

0.8

3.2

83.6

8.78

15.86

3 X 500

26.4

3.2

0.1

2.1

0.8

3.4

93.0

10.52

18.85

2)6/10(12)kV,6.35/11(12)kV,,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable

No.X Nominal Cross Section of Conductor

Nominal Diameter of Conductor

Nominal Thickness of Insulation

Nominal Thickness of Copper Tape Screen

Nominal Thickness of Inner Sheath

Nominal Thickness of Steel Tape Armouring

Nominal Thickness of PVC Sheath

Approx. Overall Diameter

Approx. Weight

Al Conductor

Cu Conductor

No. X mm2

mm

mm

mm

mm

mm

mm

mm

kg/m

kg/m

3 X 25

6.0

3.4

0.1

1.3

0.5

2.0

43.4

2.16

2.61

3 X 35

6.9

3.4

0.1

1.3

0.5

2.0

45.4

2.36

2.99

3 X50

8.2

3.4

0.1

1.4

0.5

2.2

48.8

2.69

3.54

3 X 70

9.7

3.4

0.1

1.5

0.5

2.3

52.4

3.10

4.33

3 X 95

11.3

3.4

0.1

1.5

0.5

2.4

56.1

3.56

5.26

3 X 120

12.8

3.4

0.1

1.5

0.5

2.5

59.5

4.04

6.19

3 X 150

14.2

3.4

0.1

1.5

0.5

2.6

62.7

4.49

7.19

3 X 185

15.9

3.4

0.1

1.6

0.5

2.6

66.6

5.12

8.49

3 X 240

18.3

3.4

0.1

1.7

0.5

2.8

72.4

5.99

10.42

3 X 300

20.4

3.4

0.1

1.8

0.5

3.0

77.5

6.86

12.42

3 X 400

23.2

3.4

0.1

1.9

0.8

3.2

85.4

8.97

16.05

3 X 500

26.4

3.4

0.1

2.0

0.8

3.4

93.7

10.65

19.50

3)8.7/10(15)kV,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable

No.X Nominal Cross Section of Conductor

Nominal Diameter of Conductor

Nominal Thickness of Insulation

Nominal Thickness of Copper Tape Screen

Nominal Thickness of Inner Sheath

Nominal Thickness of Steel Tape Armouring

Nominal Thickness of PVC Sheath

Approx. Overall Diameter

Approx. Weight

Al Conductor

Cu Conductor

No. X mm2

mm

mm

mm

mm

mm

mm

mm

kg/m

kg/m

3 X 25

6.0

4.5

0.1

1.4

0.5

2.1

48.6

2.53

2.98

3 X 35

6.9

4.5

0.1

1.4

0.5

2.2

50.7

2.76

3.39

3 X50

8.2

4.5

0.1

1.5

0.5

2.3

53.9

3.10

3.95

3 X 70

9.7

4.5

0.1

1.5

0.5

2.4

57.4

3.51

4.74

3 X 95

11.3

4.5

0.1

1.5

0.5

2.6

61.2

4.05

5.75

3 X 120

12.8

4.5

0.1

1.6

0.5

2.6

64.7

4.56

6.72

3 X 150

14.2

4.5

0.1

1.6

0.5

2.7

67.9

5.04

7.74

3 X 185

15.9

4.5

0.1

1.7

0.5

2.8

71.9

5.66

9.04

3 X 240

18.3

4.5

0.1

1.8

0.5

3.0

77.7

6.56

11.00

3 X 300

20.4

4.5

0.1

1.9

0.8

3.2

84.1

8.39

13.96

3 X 400

23.2

4.5

0.1

2.0

0.8

3.3

90.5

9.71

16.79

3 X 500

26.4

4.5

0.1

2.1

0.8

3.5

98.8

11.45

20.57

4)12/20(24)kV, 12.7/22(24)kV,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable

No.X Nominal Cross Section of Conductor

Nominal Diameter of Conductor

Nominal Thickness of Insulation

Nominal Thickness of Copper Tape Screen

Nominal Thickness of Inner Sheath

Nominal Thickness of Steel Tape Armouring

Nominal Thickness of PVC Sheath

Approx. Overall Diameter

Approx. Weight

Al Conductor

Cu Conductor

No. X mm2

mm

mm

mm

mm

mm

mm

mm

kg/m

kg/m

3 X 25

3 X 35

6.9

5.5

0.1

1.5

0.5

2.4

55.6

3.14

3.77

3 X50

8.2

5.5

0.1

1.5

0.5

2.5

58.6

3.49

4.34

3 X 70

9.7

5.5

0.1

1.5

0.5

2.6

62.1

3.93

5.16

3 X 95

11.3

5.5

0.1

1.6

0.5

2.6

65.7

4.46

6.16

3 X 120

12.8

5.5

0.1

1.7

0.5

2.7

69.4

5.00

7.15

3 X 150

14.2

5.5

0.1

1.7

0.5

2.8

72.6

5.49

8.19

3 X 185

15.9

5.5

0.1

1.8

0.5

3.0

76.9

6.16

9.53

3 X 240

18.3

5.5

0.1

1.9

0.8

3.2

83.9

7.87

12.31

3 X 300

20.4

5.5

0.1

2.0

0.8

3.2

88.6

8.96

14.52

3 X 400

23.2

5.5

0.1

2.1

0.8

3.5

95.4

10.35

17.43

3 X 500

26.4

5.5

0.1

2.2

0.8

3.7

103.7

12.45

20.23

5)18/30(36)kV,19/33(36)kV,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable

No.X Nominal Cross Section of Conductor

Nominal Diameter of Conductor

Nominal Thickness of Insulation

Nominal Thickness of Copper Tape Screen

Nominal Thickness of Inner Sheath

Nominal Thickness of Steel Tape Armouring

Nominal Thickness of PVC Sheath

Approx. Overall Diameter

Approx. Weight

Al Conductor

Cu Conductor

No. X mm2

mm

mm

mm

mm

mm

mm

mm

kg/m

kg/m

3 X 25

3 X 35

3 X50

8.2

8.0

0.1

1.7

0.5

2.8

70.4

4.56

5.41

3 X 70

9.7

8.0

0.1

1.7

0.5

2.9

73.9

5.04

6.26

3 X 95

11.3

8.0

0.1

1.8

0.5

3.0

77.7

5.62

7.32

3 X 120

12.8

8.0

0.1

1.9

0.8

3.2

82.8

6.99

9.15

3 X 150

14.2

8.0

0.1

1.9

0.8

3.2

85.8

7.56

10.26

3 X 185

15.9

8.0

0.1

2.0

0.8

3.3

89.9

8.30

11.67

3 X 240

18.3

8.0

0.1

2.1

0.8

3.5

95.7

9.36

13.79

3 X 300

20.4

8.0

0.1

2.2

0.8

3.6

100.6

10.51

16.07

3 X 400

23.2

8.0

0.1

2.3

0.8

3.8

107.2

11.99

19.07

3 X 500

26.4

8.0

0.1

2.4

0.8

4.0

120.1

14.15

23.85

Tags: , ,