Type MP-Gc, Mining Cable, Cu/Epr/CPE, 3/C, 8kv (ICEA S-75-381/NEMA WC-58)

 Type MP-Gc, Mining Cable, Cu/Epr/CPE, 3/C, 8kv (ICEA S-75-381/NEMA WC-58)

Product Detail

Basic Info

Model No:Type MP-GC
Type: Geïsoleerde
Conductor Type: Stranded
Toepassing: Ondergronds
Conductor Material: Koper
Materiaal Vorm: Ronde Wire
Bereik van toepassing: Mine
Certificaat: ISO9001 , CCC

Extra Informatie.

Handelsmerk:DingAn or OEM
Verpakking:Heated Steel-Wooden Drum/Steel Drum
Standaard:SGS
Oorsprong:Jiangsu Yixing, China
Gs-Code:8544492100
Productiecapaciteit:38000 Km/Year

Beschrijving

Type MP-GC, Mining Cable, Cu/EPR/CPE, 3/C, 8KV (ICEA S-75-381/NEMA WC-58)

Features
True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.

Application
High voltage distribution intended for permanent installations. Suitable for underground mining and boreholes. Can be used in aerial nstallations, ducts or direct burial.

Standards
ICEA S-75-381/NEMA WC-58 Portable and Power Feeder Cables for Use in Mines and Similar Applications.

Specifications
Maximum operating voltage: 5 kV to 35 kV 100% and 133% IL
Maximum conductor operation temperatures: Wet and dry locations
Normal: 90 °C
Emergency: 130 °C
Short Circuit: 250 °C

Engineering Information
1. Phase, Grounding and Ground Check Conductors: Soft or annealed uncoated copper compressed Class B stranding, or unilay-compressed per ASTM B8. On request, compacted strand. Sizes: 6 AWG up to 500 kcmil.
2. Conductor Shield: Semi conducting cross-linked polyethylene (XLPE).
3. Insulation: Thermoset ethylene propylene rubber (EPR).
4. Insulation Shield: Semi conducting cross-linked polyethylene (XLPE).
5. Metallic Shield: Soft annealed copper tape, 2.5 mil minimum thickness, 10% minimum overlap. Phase ID: Color printed on the extruded conducting layer, BL, WH, RE.
6. Ground Check: Thermosetting insulation yellow colored for identification.
7. Assembly: Phase conductors cabled with the ground check between the BL and WH phase conductors, two grounding conductors in inmate contact with the shields, placed on the remaining interstices, suitable fillers, as required and binder tape.
8. Jacket: Black sunlight resistance and flame retardant chlorinated polyethylene (CPE) compound. On request, PVC jacket.

Conductor Size Number of Strands Size of Each Strand Nominal Insulation Thickness Ground Conductor Size Maximum Overall Diameter Approximate Total Weight
AWG or kcmil AWG mil AWG in lb/kft
6 7 115 10 110 1.4 1129
4 7 115 8 110 1.5 1411
2 7 115 6 110 1.7 1808
1 19 115 5 110 1.8 2083
1/0 19 115 4 140 1.9 2527
2/0 19 115 3 140 2 2950
3/0 19 115 2 140 2.2 3468
4/0 19 115 1 140 2.3 4106
250 37 115 1/0 140 2.4 4691
300 37 115 1/0 140 2.5 5309
350 37 115 2/0 140 2.7 6055
500 37 115 4/0 170 3 8508

Tags: , , , , ,

Contact us

 

 

 

Success! Thanks for Your Request.