3X50mm2+1X54.6mm2+1X16mm2 NFC ABC Cable
Product Detail
Basic Info
Extra Informatie.
Beschrijving
NFC Standard 3×45+1×54.6mm2 ABC Cable, overhead line, Aerial Insulated cable abc cable
Aerial Insulated Cable with rated voltage up to and including 1KV and Aerial Bundle Cable (ABC cable)
1.Applications
The cables ard designed for aerial power lines and room-entrance wires with AC rated voltage 1kV and below.
2.Standards
ASTM ICEA BS IEC NFC GB AS/NZS etc.
3.Construction:
Conductors: Copper or Aluminium conductor round standed or compacted, AAAC,ACSR
Insulation: PVC, LDPE ,HDPE,XLPE
4. Product description
Type | Description | Application |
JKV | Rated voltage 1kV copper core PVC insulation aerial cable | Aerial fixed installation,lead door line |
JKY | Rated voltage 1kV copper core PEinsulation aerial cable | |
JKYJ | Rated voltage 1kV copper core XLPEinsulation aerial cable | |
JKLV | Rated voltage 1kV aluminum core PVC insulation aerial cable | |
JKLYJ | Rated voltage 1kV aluminum core XLPE insulation aerial cable | |
JKLJ | Rated voltage 1kV aluminum core PE insulation aerial cable | |
JKLHY | Rated voltage 1kV Al alloy core PE insulation aerial cable | |
JKLHV | Rated voltage 1kV Al alloy core PVC insulation aerial cable | |
JKLHYJ | Rated voltage 1kV Al alloy core XLPE insulation aerial cable |
5. Product Type
Duplex ABC Cable
Code*Word | Phase conductor | Bare Neutral Message | Nominal lay Length | Weight Per 1000 ft.(lbs.) |
Allo wable Amp acitles | ||||||
Size (A WG) |
Stranding | Insul Thick(Mils) |
Size (AWG) |
Stranding | Rated Strength (lbs.) |
inches | XLP | POLY | XLP | POLY | |
AAC Neutral-messenger | |||||||||||
Pekingese | 6 | 1 | 45 | 6 | 7 | 563 | 10.36 | 61 | 61 | 85 | 70 |
Collie | 6 | 7 | 45 | 6 | 7 | 563 | 10.36 | 64 | 64 | 85 | 70 |
Dachshund | 4 | 1 | 45 | 4 | 7 | 881 | 10.36 | 92 | 92 | 115 | 90 |
Spaniel | 4 | 7 | 45 | 4 | 7 | 881 | 10.36 | 96 | 96 | 115 | 90 |
Doberman | 2 | 7 | 45 | 2 | 7 | 1350 | 14.88 | 147 | 147 | 150 | 120 |
Malemute | 1/0 | 9 | 60 | 1/0 | 7 | 1990 | 14.88 | 234 | 234 | 205 | 160 |
Triplex ABC Cable
Code*Word | Phase conductor | Bare Neutral Message | Nominal lay Length | Weight Per 1000 ft.(lbs.) |
Allo wable Amp acitles | ||||||
Size (A WG) |
Stranding | Insul Thick(Mils) |
Size (AWG) |
Stranding | Rated Strength (lbs.) |
inches | XLP | POLY | XLP | POLY | |
AAC Neutral-messenger | |||||||||||
Pateela | 6 | 7 | 45 | 6 | 7 | 563 | 14.88 | 103 | 103 | 85 | 70 |
Oyster | 4 | 7 | 45 | 4 | 7 | 881 | 14.88 | 154 | 154 | 115 | 90 |
Clam | 2 | 7 | 45 | 2 | 7 | 1350 | 20.58 | 233 | 233 | 150 | 120 |
Murex | 1/0 | 7 | 60 | 1/0 | 7 | 1990 | 20.58 | 374 | 374 | 205 | 160 |
Purpura | 1/0 | 9 | 60 | 1/0 | 7 | 1990 | 20.58 | 368 | 368 | 205 | 160 |
Nassa | 2/0 | 7 | 60 | 2/0 | 7 | 2510 | 25.42 | 462 | 462 | 235 | 185 |
Melita | 3/0 | 17 | 60 | 3/0 | 19 | 3310 | 29.97 | 562 | 562 | 275 | 215 |
Portunus | 4/0 | 18 | 60 | 4/0 | 19 | 4020 | 29.97 | 696 | 696 | 315 | 245 |
Nannynose | 336.4 | 19 | 60 | 336.4 | 19 | 6146 | 38.79 | 1118 | 1118 | 420 | 325 |
*Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Chihuahua/XLP) +Conductor temperature of 90 for XLP,75 for Poly;ambient temperature of 40;emissivity 0.2;2ft./sec.Wind in sun. |
Quadruplex ABC Cable
Code*Word | Phase conductor | Bare Neutral Message | Nominal lay Length | Weight Per 1000 ft.(lbs.) |
Allo wable Amp acitles | ||||||
Size (A WG) |
Stranding | Insul Thick(Mils) |
Size (AWG) |
Stranding | Rated Strength (lbs.) |
inches | XLP | POLY | XLP | POLY | |
AAC Neutral-messenger | |||||||||||
Clydessdale | 4 | 1 | 45 | 4 | 7 | 881 | 20.58 | 198 | 198 | 100 | 80 |
Pinto | 4 | 7 | 45 | 4 | 7 | 881 | 20.58 | 211 | 211 | 100 | 80 |
Mustang | 2 | 7 | 45 | 2 | 7 | 1350 | 25.42 | 318 | 318 | 135 | 105 |
Criollo | 1/0 | 9 | 60 | 1/0 | 7 | 1990 | 25.42 | 503 | 503 | 180 | 140 |
Percheron | 2/0 | 11 | 60 | 2/0 | 7 | 2510 | 29.97 | 619 | 619 | 205 | 160 |
Hanovarian | 3/0 | 17 | 60 | 3/0 | 19 | 3310 | 35.18 | 764 | 764 | 235 | 185 |
Oldenburg | 4/0 | 18 | 60 | 4/0 | 19 | 4020 | 35.18 | 945 | 945 | 275 | 210 |
Lippizaner | 336.4 | 19 | 80 | 336.4 | 19 | 6146 | 38.79 | 1519 | 1519 | 370 | 280 |
*Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Chihuahua/XLP) +Conductor temperature of 90 for XLP,75 for Poly;ambient temperature of 40;emissivity 0.2;2ft./sec.Wind in sun |