450/750V, pvc Sheath Control Cable, 4mm2
Product Detail
Basic Info
Extra Informatie.
Beschrijving
Specifications
Control cable,
Rated voltage 0.6/1KV and below
PVC or XLPE insulated, armoured or unarmored cable
PVC sheathed control cable
PVC sheath control cable
1)Max.Rated Temperature Of The Conductor Is 90oc
2)Max.Short-Circuit Temperature Of The Conductor Shall Not Exceed 250oc
3)Max.Sustaining Period Not Ecxeed 5 Seconds.
4)Installation Temperature Of Cable Shall Not Below 0oc .
5)Recommended Permissible Bending Radius:
A)For Non-Armormed Cable,Shall Not Be Less Than 6 Times Of The Cable’s Overall Diameter.
B)For Armored Or Copper Tape Shielded Cable,Shall Not Be Less Than 12 Times Of The Cable’s Overall Diameter.
C)For Soft Cable With Shield Layer,Shall Not Be Less Than 6 Times Of The Cable’s Overall Diameter.
Other Special Characteristics:Design And Manufacture According To Customers’ Request
Control Cable Tye and General Introduction
Type | Name | Application Site |
KVV/KYJV | Copper conductor, PVC/XLPE insulation, PVC sheath control cable | For laying doors, in trenches and in ducts, for fixed installation. |
KYJ(F)V | Copper conductor, Irradiated cross-linked insulation, PVC sheath control cable | With flame retardant property and conductor Max.Temperature of 90-150°C |
KVV22 KYJV22 | Copper conductor, PVC/XLPE insulation, PVC sheath control cable with steel tape armored | For laying doors, in ground, can withstand heavier mechanical force and for fixed installation. |
KYJ(F)V22 | Copper conductor, Irradiated cross-linked insulation, PVC sheath control cable with steel tape armored | With flame retardant property and conductor Max.Temperature of 90-150°C, which can withstand heavier mechanical force |
KVVP KYJVP | Copper conductor, PVC/XLPE insulation, PVC sheath with copper wire braided shield control cable | For laying doors, in trenches and in ducts, such cable has the stable structure and excellent properties of anti-interference. |
KVVP2 KYJVP2 | Copper conductor, PVC/XLPE insulation, PVC sheath with copper tape wrapped shield control cable | For laying doors, in trenches and in ducts, the cable has stable structure and excellent properties of anti-interference also can withstand heavier mechanical force. |
KVVP22 KYJVP22 | Copper conductor, PVC/XLPE insulation, PVC sheath with copper wire braided shield and Steel tape armored control cable | For laying in doors, in ground and be able to withstand heavier mechanical force and good anti-interference properties for fixed installation. |
KVVP2-22 KYJVP2-22 | Copper conductor, PVC/XLPE insulation, PVC sheath with copper tape wrapped shield and Steel tape armored control cable | For laying in doors, in ground and be able to withstand heavier mechanical force and good anti-interference properties for fixed installation. |
KVV32 KYJV32 | Copper conductor, PVC/ XLPE insulation, PVC sheath control cable with steel wire armored | For laying doors, in ground, able to withstand heavier mechanical force and for fixed installation. |
KVVP32 KYJVP32 | Copper conductor, PVC/XLPE insulation, PVC sheath/ copper wires braided shield and steel wire armored control cable | For laying doors, in ground, able to withstand heavier mechanical force and for fixed installation. |
KVVP2-32 | Copper conductor, PVC insulation, PVC sheath with Copper tape wrapped shield and steel wire armored control cable | For laying doors, in ground, able to withstand heavier mechanical force and for fixed installation. |
KVVR | Copper conductor , PVC insulation and PVC sheath flexible control cable | For laying doors, connecting movable devices which can be used for movable installation. |
KVVRP | Copper conductor, PVC insulation and PVC sheath flexible control cable with copper wire braided shield | For laying doors with good property of shielding and anti-interference, for movable installation but can’t withstand external mechanical force. |
KVVRP2 | Copper conductor, PVC insulation and PVC sheath flexible control cable with copper tape wrapped shield | For laying doors with good property of shielding and anti-interference, for movable installation but can’t withstand external mechanical force. |
NH-KVV | Copper conductor, PVC insulation and PVC sheath fire-resistance control cable | Excellent property of flame-retardance and applies to high requirements of fire-fighting situation. |
Packaging & Shipping
1).Wrapped in rolls/coils/rings with Plastic film for small diameter cables like building wires.
2).Treated wooden/steel-wooden drums for big diameter cables.
3).Cables are normally supplied in lengths of 100 meters,500 meters and 1000 meters according to cable size.Other
Length could be supplied if required.
- Next: Audio Instrument Cable, for IEC ASTM BS Standards