Medium Voltage 10kv Power Aluminium Urd-Kabel


                                 Medium Voltage 10kv Power Aluminium Urd-Kabel

Basic Info

Model No.
ABC Cable

Toepassing
Bouw ,
Boven het hoofd ,
Industrieel ,
Centrale

Voltage
Laag-en middenspanning Kabel

Stroom
DC & AC

Isolatiemateriaal
XLPE

Materiaal Vorm
Ronde Wire

Certificaat
ISO ,
CCC ,
CE ,
UL

Extra Informatie.

Handelsmerk
HUATONG

Verpakking
Drum

Standaard
GB/T 12527

Oorsprong
China

Gs-Code
8544492100

Productiecapaciteit
5000km/Month

Beschrijving

Aluminium Secondary UD Cable
Aluminium Conductors. Polythylene or Crosslinked Polyethylene Insulation.
ABC Cables Applications:
Used to supply 3 phase power, usually from a pole-mounted transformer, to the user’s service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for crosslinked polyethylene (XLP) insulated conductors. 
ABC Cables Construction:
Conductors are concentrically stranded, compressed 1350-H19 aluminum. Insulated with either polyethylene or XLP crosslinked polyethylene. Neutral messengers are concentrically stranded 6201, AAC, or ACSR.One conductor is manufactured with an extruded ridge for phase identification.
ABC Cables Standards:
1.B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
2.B-231 Aluminum conductors, Concentric-Lay-Stranded.
3.B-232 Aluminum Conductors, Concentric- Lay-Stranded, Coated Steel Reinforced (ACSR).
4.B-399 Concentric-Lay-Stranded, 6201-T81 Aluminum Alloy Conductors.
5.B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
6.Quadruplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474.
ABC Cables Using Properties
1.Rated Voltage:0.6/1kV
2.Cable installation temperature not less than -20°C
3.Max. temperature of cable at short circuit(The max. duration does not exceed 5 minutes)
   For XLPE insulation is 250°C.
   For HDPE insulation is 150 °C.
4.The Max. bending radius of cable shall not be less than 20Dmm(D overall diameter of cable)
Type of ABC Cable
1.Duplex Service Drop:To supply 120 volt aerial service for temporary service at construction sites,outdoor or street lighting . For service at 600 volts or lower at a conductor temperature of 75 maximum.
2.Triplex Service Drop: To supply power from the ulility`s lines to the consumer`s weatherhead. For service at 600 volts or less(phase to phase ) at a conductor temperature of 75 maximum for PE insulation or 90 maximum for XLPE insulation .
3.Quadruplex Service Drop: Used to supply 3 phase power , usually from a pole-mounted transformer to the use`s servic head where connection to the service entance cable is made . To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for PE insulated conductors or 90 for XLPE insulated conductors.

ASTM B-230, B-231 and ICEA S-66-524
UL Standard 854 for type USE
Federal Specification JC-30B NEC

Code Name

Phase Conductor

Neutral

Single Phase Conductor(in)

Outside diameter(in)

Weight Per 1000ft (lbls)

Ampacity

Size AWG

Strand

Insulation Thickness (mls)

Size AWG

Strand

Insulation Thickness (mls)

Direct Burial

In Duct

Tulsa

4

7/w

60

4

7/w

60

.345

.833

258

119

85

Dyke

2

7/w

60

4

7/w

60

.403

.938

346

153

115

Wittenberg

2

7/w

60

2

7/w

60

.403

.973

375

153

115

Notre Dame

1/0

19/w

80

2

7/w

60

.522

1.188

541

198

150

Purdue

1/0

19/w

80

1/0

19/w

80

.522

1.260

596

198

150

Syracuse

2/0

19/w

80

1/0

19/w

80

.566

1.316

664

225

170

Lafayette

2/0

19/w

80

2/0

19/w

80

.566

1.367

720

225

170

Swarthmore

3/0

19/w

80

1/0

19/w

80

.616

1.430

805

250

195

Davidson

3/0

19/w

80

3/0

19/w

80

.616

1.487

874

250

195

Wake Forest

4/0

19/w

80

2/0

19/w

80

.672

1.560

979

290

225

Earlham

4/0

19/w

80

4/0

19/w

80

.672

1.623

1066

290

225

Slippery Rock

350

37/w

95

4/0

19/w

80

.851

1.945

1544

385

305

Wofford

500

37/w

95

350

37/w

95

.851

2.348

2174

467

420

Windham

750

61/w

110

500

37/w

95

.979

2.850

2542

615

492

 