Koper Conductors met XLPE Insulation en Bare Neutral
Product Detail
Basic Info
Extra Informatie.
Beschrijving
1. Description
* They are composed of on eor more insulated conductors and one neutral (bare or insulated )
conductor.
* They are required as two ( Duplex) or three (Triplex) or four (Quadru -plex) conductors.
* As per NEMA WC 7/ IEC 60228.
2. Technical Information
Two conductors (Duplex)
Phase | Max. Resitance | Approx. Overall | Approx. | |
Sectional area |
Insulation thickness |
at 20ºC | Diameter | Weight |
mm² | mm | Ω/km | mm | kg/km |
10 | 1.2 | 1.830 | 10.7 | 198 |
16 | 1.2 | 1.150 | 12.8 | 307 |
25 | 1.2 | 0.727 | 15.3 | 469 |
35 | 1.2 | 0.524 | 17.6 | 650 |
50 | 1.5 | 0.387 | 21.2 | 898 |
70 | 1.5 | 0.268 | 24.5 | 1247 |
95 | 1.5 | 0.193 | 28.3 | 1736 |
120 | 1.7 | 0.153 | 31.8 | 2170 |
Three conductors (Triplex)
Phase | Max. Resitance | Approx. Overall | Approx. | |
Sectional area |
Insulation thickness |
at 20ºC | Diameter | Weight |
mm² | mm | Ω/km | mm | kg/km |
10 | 1.2 | 1.830 | 13.7 | 305 |
16 | 1.2 | 1.150 | 15.8 | 471 |
25 | 1.2 | 0.727 | 18.5 | 719 |
35 | 1.2 | 0.524 | 20.7 | 991 |
50 | 1.5 | 0.387 | 25.0 | 1357 |
70 | 1.5 | 0.268 | 28.7 | 1900 |
95 | 1.5 | 0.193 | 32.4 | 2631 |
120 | 1.7 | 0.153 | 36.6 | 3285 |
Four Conductors (Quadruplex)
Phase | Max. Resitance | Approx. Overall | Approx. | |
Sectional area |
Insulation thickness |
at 20ºC | Diameter | Weight |
mm² | mm | Ω/km | mm | kg/km |
10 | 1.2 | 1.830 | 16.3 | 413 |
16 | 1.2 | 1.150 | 18.8 | 634 |
25 | 1.2 | 0.727 | 22.0 | 970 |
35 | 1.2 | 0.524 | 24.6 | 1332 |
50 | 1.5 | 0.387 | 29.8 | 1821 |
70 | 1.5 | 0.268 | 34.2 | 2553 |
95 | 1.5 | 0.193 | 38.6 | 3526 |
120 | 1.7 | 0.153 | 43.5 | 4579 |
3.SERVICING
Purpose:
To establish and maintain a procedure for performing and verifying that our service meets specified requirements and that a suitable method of feedback exists from the customer back to the appropriate individual or department within YIFANG.
Scope:
YIFANG does not currently have any contracts that obligate the company to provide installation or service above and beyond normal product service and delivery. Service activity not specified by contract (such as the treatment of a customer complaint) shall be determined and performed free of charge on a case by case basis. Service concerns will be recorded and will provide a feed-back system as required by the customer.
- Next: Twisted Conductor Twin AAC ACSR AAAC Vibration Rresistant