Low Voltage ABC Aerial Bundled Cable
Product Detail
Basic Info
Extra Informatie.
Beschrijving
Low Voltage ABC Aerial Bundled Cable
ABC overhead Cable overhead insulated products adopt the IEC standards, can also be made complying with BS, DIN, ASTM, JIS, GOST, NFC, CSA etc. The overhead insulated cables are suitable for aerial distribution electrical lines with rated AC voltage U(Um)10(12)KV and 35(42)KV.
The min temeperature of laying cable is not lower than -20 degree centigrade.
The max. Temperature of HDPE insulated cable is 150 degree centigrade, and that of the XLPE insulated cable is 250 degree centigrade when short circuit(5 seconds)
Product Details:
Insulation Material PVC OR XLPE
Application Overhead
Jacket NON THEATH
Conductor Material COPPER OR ALUMINIUM
Place of Origin Henan China
Brand Name: JIAPU
Model Number ABC, JKLYJ, JKLV
Our overhead insulated cable have formed a system, such as single core, two-core, three core and four core. There are conductors of aluminium, aluminium alloy or aluminium steel-reinforced. We can manufacture the overhead insulated cable not only in accordance with China`s standard GB12527-90 but also the other standards and special requiement by the custormers.
Specification:
(1)Self-supporting
Phase |
Phase |
Phase |
Approx.Overall Diameter |
Max. D.C. Resistance of Conductor at 20ºC |
|||
AAC+UV-XLPE |
Compact Conductor |
UV-XLPE Insulation |
|||||
No.X Normal Cross Section of Cores |
No.of Al Wires |
Overall Diameter |
Normal Thickness |
Min. |
Diameter |
||
No. X mm2 |
– |
mm |
mm |
mm |
mm |
mm |
ohm/km |
1 X 10 |
7 |
4.05 |
1.0 |
0.8 |
6.05 |
6.05 |
3.08 |
1 X 16 |
7 |
4.8 |
1.2 |
0.98 |
7.2 |
7.20 |
1.91 |
1 X 25 |
7 |
6 |
1.2 |
0.98 |
8.4 |
8.40 |
1.20 |
1 X 35 |
7 |
7.0 |
1.4 |
1.16 |
9.8 |
9.80 |
0.868 |
1 X 50 |
7 |
8.3 |
1.4 |
1.16 |
11.1 |
11.10 |
0.641 |
1 X 70 |
19 |
9.8 |
1.4 |
1.16 |
12.6 |
12.60 |
0.443 |
1 X 95 |
19 |
11.6 |
1.6 |
1.34 |
14.8 |
14.80 |
0.320 |
1 X 120 |
19 |
13 |
1.6 |
1.34 |
16.2 |
16.20 |
0.253 |
1 X 150 |
19 |
14.6 |
1.8 |
1.52 |
18.2 |
18.20 |
0.206 |
1 X 185 |
36 |
16.2 |
2.0 |
1.70 |
20.2 |
20.20 |
0.164 |
1 X 240 |
36 |
18.4 |
2.2 |
1.88 |
22.8 |
22.80 |
0.125 |
2 X 10 |
7 |
4.05 |
1.0 |
0.8 |
6.05 |
12.10 |
3.08 |
2 X 16 |
7 |
4.8 |
1.2 |
0.98 |
7.2 |
14.40 |
1.91 |
2 X 25 |
7 |
6 |
1.2 |
0.98 |
8.4 |
16.80 |
1.20 |
2 X 35 |
7 |
7.0 |
1.4 |
1.16 |
9.8 |
19.60 |
0.868 |
2 X 50 |
7 |
8.3 |
1.4 |
1.16 |
11.1 |
22.20 |
0.641 |
2 X 70 |
19 |
9.8 |
1.4 |
1.16 |
12.6 |
25.20 |
0.443 |
2 X 95 |
19 |
11.6 |
1.6 |
1.34 |
14.8 |
29.60 |
0.320 |
2 X 120 |
19 |
13 |
1.6 |
1.34 |
16.2 |
32.40 |
0.253 |
2 X 150 |
19 |
14.6 |
1.8 |
1.52 |
18.2 |
36.40 |
0.206 |
2 X 185 |
36 |
16.2 |
2.0 |
1.70 |
20.2 |
40.40 |
0.164 |
2 X 240 |
36 |
18.4 |
2.2 |
1.88 |
22.8 |
45.60 |
0.125 |
3 X 10 |
7 |
4.05 |
1.0 |
0.8 |
6.05 |
13.07 |
3.08 |
3 X 16 |
7 |
4.8 |
1.2 |
0.98 |
7.2 |
15.55 |
1.91 |
3 X 25 |
7 |
6 |
1.2 |
0.98 |
8.4 |
18.14 |
1.20 |
3 X 35 |
7 |
7.0 |
1.4 |
1.16 |
9.8 |
21.17 |
0.868 |
3 X 50 |
7 |
8.3 |
1.4 |
1.16 |
11.1 |
23.98 |
0.641 |
3 X 70 |
19 |
9.8 |
1.4 |
1.16 |
12.6 |
27.22 |
0.443 |
3 X 95 |
19 |
11.6 |
1.6 |
1.34 |
14.8 |
31.97 |
0.320 |
3 X 120 |
19 |
13 |
1.6 |
1.34 |
16.2 |
34.99 |
0.253 |
3 X 150 |
19 |
14.6 |
1.8 |
1.52 |
18.2 |
39.31 |
0.206 |
3 X 185 |
36 |
16.2 |
2.0 |
1.70 |
20.2 |
43.63 |
0.164 |
3 X 240 |
36 |
18.4 |
2.2 |
1.88 |
22.8 |
49.25 |
0.125 |
4 X 10 |
7 |
4.05 |
1.0 |
0.8 |
6.05 |
14.64 |
3.08 |
4 X 16 |
7 |
4.8 |
1.2 |
0.98 |
7.2 |
17.42 |
1.91 |
4 X 25 |
7 |
6 |
1.2 |
0.98 |
8.4 |
20.33 |
1.20 |
4 X 35 |
7 |
7.0 |
1.4 |
1.16 |
9.8 |
23.72 |
0.868 |
4 X 50 |
7 |
8.3 |
1.4 |
1.16 |
11.1 |
26.86 |
0.641 |
4 X 70 |
19 |
9.8 |
1.4 |
1.16 |
12.6 |
30.49 |
0.443 |
4 X 95 |
19 |
11.6 |
1.6 |
1.34 |
14.8 |
35.82 |
0.320 |
4 X 120 |
19 |
13 |
1.6 |
1.34 |
16.2 |
39.20 |
0.253 |
4 X 150 |
19 |
14.6 |
1.8 |
1.52 |
18.2 |
44.04 |
0.206 |
4 X 185 |
36 |
16.2 |
2.0 |
1.70 |
20.2 |
48.88 |
0.164 |
4 X 240 |
36 |
18.4 |
2.2 |
1.88 |
22.8 |
55.18 |
0.125 |
(2) Phase + Neutral
Phase |
Neutral |
Phase |
Neutral |
Approx.Overall Diameter |
Max. D.C. Resistance of Conductor at 20ºC |
||||
AAC+UV-XLPE |
AAAC |
Compact Conductor |
UV-XLPE Insulation |
Conductor |
|||||
Phase |
Neutral |
||||||||
No.X Normal Cross Section of Cores |
No.X Normal Cross Section of Cores |
No.of Al.Wire |
Overall Dia. |
Normal Thickness |
Min. |
No./Dia. of Al Alloy Wire |
|||
No. X mm2 |
No. X mm2 |
– |
mm |
mm |
Min. |
No./mm |
mm |
ohm/km |
ohm/km |
1 X 16 |
1 X 16 |
7 |
4.8 |
1.2 |
0.98 |
7/1.70 |
12.30 |
1.91 |
2.217 |
1 X 25 |
1 X 25 |
7 |
6 |
1.2 |
0.98 |
7/2.10 |
14.70 |
1.20 |
1.393 |
1 X 35 |
1 X 35 |
7 |
7.0 |
1.4 |
1.16 |
7/2.50 |
17.30 |
0.868 |
1.007 |
1 X 50 |
1 X 50 |
7 |
8.3 |
1.4 |
1.16 |
7/3.00 |
20.10 |
0.641 |
0.744 |
1 X 70 |
1 X 70 |
19 |
9.8 |
1.4 |
1.16 |
7/3.50 |
23.10 |
0.443 |
0.514 |
1 X 95 |
1 X 95 |
19 |
11.6 |
1.6 |
1.34 |
19/2.50 |
27.30 |
0.320 |
0.371 |
1 X 120 |
1 X 120 |
19 |
13 |
1.6 |
1.34 |
19/2.80 |
30.20 |
0.253 |
0.294 |
1 X 150 |
1 X 150 |
19 |
14.6 |
1.8 |
1.52 |
37/2.25 |
33.95 |
0.206 |
0.239 |
1 X 185 |
1 X 185 |
36 |
16.2 |
2.0 |
1.70 |
37/2.50 |
37.70 |
0.164 |
0.190 |
1 X 240 |
1 X 240 |
36 |
18.4 |
2.2 |
1.88 |
61/2.25 |
43.05 |
0.125 |
0.145 |
2 X 16 |
1 X 16 |
7 |
4.8 |
1.2 |
0.98 |
7/1.70 |
14.04 |
1.91 |
2.217 |
2 X 25 |
1 X 25 |
7 |
6 |
1.2 |
0.98 |
7/2.10 |
16.63 |
1.20 |
1.393 |
2 X 35 |
1 X 35 |
7 |
7.0 |
1.4 |
1.16 |
7/2.50 |
19.51 |
0.868 |
1.007 |
2 X 50 |
1 X 50 |
7 |
8.3 |
1.4 |
1.16 |
7/3.00 |
22.46 |
0.641 |
0.744 |
2 X 70 |
1 X 70 |
19 |
9.8 |
1.4 |
1.16 |
7/3.50 |
25.70 |
0.443 |
0.514 |
2 X 95 |
1 X 95 |
19 |
11.6 |
1.6 |
1.34 |
19/2.50 |
30.31 |
0.320 |
0.371 |
2 X 120 |
1 X 120 |
19 |
13 |
1.6 |
1.34 |
19/2.80 |
33.41 |
0.253 |
0.294 |
2 X 150 |
1 X 150 |
19 |
14.6 |
1.8 |
1.52 |
37/2.25 |
37.55 |
0.206 |
0.239 |
2 X 185 |
1 X 185 |
36 |
16.2 |
2.0 |
1.70 |
37/2.50 |
41.69 |
0.164 |
0.190 |
2 X 240 |
1 X 240 |
36 |
18.4 |
2.2 |
1.88 |
61/2.25 |
47.41 |
0.125 |
0.145 |
3 X 16 |
1 X 16 |
7 |
4.8 |
1.2 |
0.98 |
7/1.70 |
16.15 |
1.91 |
2.217 |
3 X 25 |
1 X 25 |
7 |
6 |
1.2 |
0.98 |
7/2.10 |
19.06 |
1.20 |
1.393 |
3 X 35 |
1 X 35 |
7 |
7.0 |
1.4 |
1.16 |
7/2.50 |
22.32 |
0.868 |
1.007 |
3 X 50 |
1 X 50 |
7 |
8.3 |
1.4 |
1.16 |
7/3.00 |
25.59 |
0.641 |
0.744 |
3 X 70 |
1 X 70 |
19 |
9.8 |
1.4 |
1.16 |
7/3.50 |
29.22 |
0.443 |
0.514 |
3 X 95 |
1 X 95 |
19 |
11.6 |
1.6 |
1.34 |
19/2.50 |
34.42 |
0.320 |
0.371 |
3 X 120 |
1 X 120 |
19 |
13 |
1.6 |
1.34 |
19/2.80 |
37.87 |
0.253 |
0.294 |
3 X 150 |
1 X 150 |
19 |
14.6 |
1.8 |
1.52 |
37/2.25 |
42.56 |
0.206 |
0.239 |
3 X 185 |
1 X 185 |
36 |
16.2 |
2.0 |
1.70 |
37/2.50 |
47.25 |
0.164 |
0.190 |
3 X 240 |
1 X 240 |
36 |
18.4 |
2.2 |
1.88 |
61/2.25 |
53.63 |
0.125 |
0.145 |
(3) Phase + Neutral + Service Connection
Phase |
Neutral |
Service Connection |
Phase |
Neutral |
Service Connection |
Approx.Overall Diameter of Bundled Cable |
|||||
AAC+UV-XLPE |
AAAC+UV-XLPE |
AAC+UV-XLPE |
Conductor |
UV-XLPE |
Conductor |
UV-XLPE |
Compact Conductor |
UV-XLPE |
|||
No.X Normal Cross Section of Cores |
No.X Normal Cross Section of Cores |
No.X Normal Cross Section of Cores |
No. of Al. Wire |
Overall Dia. |
Normal |
No./Dia. of Al. Wire |
Normal |
No. of Al. Wire |
Overall Dia. |
Normal |
|
No. X mm2 |
No. X mm2 |
No. X mm2 |
– |
mm |
mm |
mm |
mm |
No./mm |
mm |
mm |
mm |
3 X 16 |
1 X 50 |
1 X 16 |
7 |
4.8 |
1.2 |
7/3.0 |
1.4 |
7 |
4.8 |
1.2 |
26.2 |
3 X 25 |
1 X 50 |
1 X 16 |
7 |
6 |
1.2 |
7/3.0 |
1.4 |
7 |
4.8 |
1.2 |
28.6 |
3 X 35 |
1 X 50 |
1 X 16 |
7 |
7.0 |
1.4 |
7/3.0 |
1.4 |
7 |
4.8 |
1.2 |
31.4 |
3 X 50 |
1 X 50 |
1 X 16 |
7 |
8.3 |
1.4 |
7/3.0 |
1.4 |
7 |
4.8 |
1.2 |
34 |
3 X 70 |
1 X 50 |
1 X 16 |
19 |
9.8 |
1.4 |
7/3.0 |
1.4 |
7 |
4.8 |
1.2 |
37 |
3 X 95 |
1 X 50 |
1 X 16 |
19 |
11.6 |
1.6 |
7/3.0 |
1.4 |
7 |
4.8 |
1.2 |
41.4 |
3 X 120 |
1 X 50 |
1 X 16 |
19 |
13 |
1.6 |
7/3.0 |
1.4 |
7 |
4.8 |
1.2 |
44.2 |
3 X 16 |
1 X 50 |
2 X 16 |
7 |
4.8 |
1.2 |
7/3.0 |
1.4 |
7 |
4.8 |
1.2 |
26.2 |
3 X 25 |
1 X 50 |
2 X 16 |
7 |
6 |
1.2 |
7/3.0 |
1.4 |
7 |
4.8 |
1.2 |
28.6 |
3 X 35 |
1 X 50 |
2 X 16 |
7 |
7.0 |
1.4 |
7/3.0 |
1.4 |
7 |
4.8 |
1.2 |
31.4 |
3 X 50 |
1 X 50 |
2 X 16 |
7 |
8.3 |
1.4 |
7/3.0 |
1.4 |
7 |
4.8 |
1.2 |
34 |
3 X 70 |
1 X 50 |
2 X 16 |
19 |
9.8 |
1.4 |
7/3.0 |
1.4 |
7 |
4.8 |
1.2 |
37 |
3 X 95 |
1 X 50 |
2 X 16 |
19 |
11.6 |
1.6 |
7/3.0 |
1.4 |
7 |
4.8 |
1.2 |
41.4 |
3 X 120 |
1 X 50 |
2 X 16 |
19 |
13 |
1.6 |
7/3.0 |
1.4 |
7 |
4.8 |
1.2 |
44.2 |
Contact us
Soortgelijk of gerelateerd
-
PVC/XLPE Insulated Aerial Bundled Cable, ABC Cable, overhead Cable, ASTM, BS, NFC, IEC, DIN Standard
-
Triplex Service Drop Cable with ACSR Neutral, Twisted 600 V Triplex (ANSI/ICEA S-76-474)
-
Triplex Service Drop Cable with AAAC Neutral, Twisted 600 V Triplex (ANSI/ICEA S-76-474)
-
Triplex Service Drop Cable with AAC Neutral, Twisted 600 V Triplex (ANSI/ICEA S-76-474)