Overhead Bundled Aluminum Cable / Quadruplex Drop Service
Product Detail
Basic Info
Extra Informatie.
Beschrijving
Specifications
Standard: National Standard IEC and ASTM
Rated Voltage: 0.6/1KV, 11KV, 33KV
Construction: Phase conductor: Aluminum stranded(AAC)
Neutral conductor: Aluminum stranded(AAC), aluminum alloy stranded(AAAC), aluminum conductor steel reinforced(ACSR)
Insulation: XLPE or PE
Application: The cables are designed for aerial power lines and room-entrance wires with voltage up to and including 0.6/1KV.
Uesd for overhead service application such as street linghting, outdoor lighting and temporary service for cunstruction. Which improves the safety and reliance of electrified wire netting.
1 Type: Duplex Service Drop, Triplex Service Drop, Quadruplex Service Drop
A Duplex Service Drop
Applications: To supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower at a conductor temperature of 75 maximum.
B Triplex Service Drop
Applications: To supply power from the ulility`s lines to the consumer`s weatherhead. For service at 600 volts or less(phase to phase ) at a conductor temperature of 75 maximum for PE insulation or 90 maximum for XLPE insulation.
C Quadruplex Service Drop
Applications: Used to supply 3 phase power, usually from a pole-mounted transformer to the use`s servic head where connection to the service entance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for PE insulated conductors or 90 for XLPE insulated conductors.
2 Construction
A Phase Conductor construction: The phase conductor is aluminum alloy 1350-H19 hard-drawn, compressed concentric-lay-stranded.
B Neutral Conductor Construction
Cable assemblies are available with the following neutral conductors:
Aluminum conductors, coated-steel reinforced (ACSR), concentric-lay-stranded
Aluminum alloy 1350-H19 hard-drawn, concentric-lay-stranded
Aluminum alloy 6201-T81, concentric-lay-stranded
C Insulation Material
The standard insulation on the phase conductor is black low-density crosslinked polyethylene (XLPE)
Alternatively, black linear low-density polyethylene (LDPE) insulation with a 75° C temperature rating is available upon request.
PEC mm2 | conductor structure | Approx. | ||||||
Phase | Neutral(Bare ACSR) | insulation | insulation | Overall | Approx. | packing | ||
(Compacted AL) | Aluminium | Steel | material | Thickness | Diameter | Weight | Meters Per | |
(No./mm) | (No./mm) | (No./mm) | (mm) | (mm) | (kg/km) | Drum | ||
1×16+1×16 | 7/1.72 | 6/1.72 | 1/1.72 | XLPE | 1.2 | 12.5 | 121.9 | 250-4000m |
1×25+1×25 | 7/2.15 | 6/2.15 | 1/2.15 | 1.2 | 14.9 | 182.2 | 250-4000m | |
1×35+1×35 | 7/2.54 | 6/2.54 | 1/2.54 | 1.4 | 17.5 | 254.7 | 250-3500m | |
1×50+1×50 | 7/2.92 | 6/2.92 | 1/2.92 | 1.4 | 20.1 | 333.9 | 250-3000m | |
1×70+1×70 | 19/2.15 | 12/2.15 | 17/2.15 | 1.4 | 23.6 | 382.2 | 250-3000m | |
1×95+1×95 | 19/2.54 | 12/5.24 | 17/5.24 | 1.6 | 27.6 | 528.2 | 250-3000m | |
2×16+1×16 | 7/1.72 | 6/1.72 | 1/1.72 | (HDPE) | 1.2 | 14.2 | 187.6 | 250-4000m |
2×25+1×25 | 7/2.15 | 6/2.15 | 1/2.15 | 1.2 | 16.7 | 273.8 | 250-3500m | |
2×35+1×35 | 7/2.54 | 6/2.54 | 1/2.54 | 1.4 | 19.7 | 386.9 | 250-3500m | |
2×50+1×50 | 7/2.92 | 6/2.92 | 1/2.92 | 1.4 | 22.5 | 506 | 250-3000m | |
2×70+1×70 | 19/2.15 | 12/2.15 | 7/2.15 | 1.4 | 26.1 | 617.2 | 250-3000m | |
2×95+1×95 | 19/2.54 | 12/5.24 | 7/5.24 | 1.6 | 30.5 | 850.9 | 250-3000m | |
3×16+1×16 | 7/1.72 | 6/1.72 | 1/1.72 | 1.2 | 16.3 | 253.3 | 250-3500m | |
3×25+1×25 | 7/2.15 | 6/2.15 | 1/2.15 | 1.2 | 19.1 | 371.9 | 250-3500m | |
3×35+1×35 | 7/2.54 | 6/2.54 | 1/2.54 | 1.4 | 22.5 | 519.1 | 250-3000m | |
3×50+1×50 | 7/2.92 | 6/2.92 | 1/2.92 | 1.4 | 25.7 | 678.1 | 250-3000m | |
3×70+1×70 | 19/2.15 | 12/2.15 | 7/2.15 | 1.4 | 29.7 | 1024.3 | 250-3000m | |
2×95+1×95 | 19/2.54 | 12/2.54 | 7/2.54 | 1.6 | 34.6 |
Specifications
1.Conductor: aluminum or copper
2. Insulation: XLPEor PVC
3.Stranded or solid conductor
4. IECstandard
5. abc cables
low voltage overhead bundled cable ABC
Specifications
ABC aerial bundle cable withAluminium stranded conductor(compacted or non- compacted), AAAC or ACSR messenger core.
Aluminium stranded conductor(compacted or non- compacted), AAAC messenger core(or ACSR messenger core), XLPE(or HDPE) insulated, Twisted (or Parallel)power cable
The product is a new type of aerial cable for power transmitting, It is extensively used in overhead power transmission line, It improves the safety and reliance of electrified wire netting.
SPEC mm2 | conductor structure | Approx. | ||||||
Phase | Neutral(Bare ACSR) | insulation | insulation | Overall | Approx. | packing | ||
(Compacted AL) | Aluminium | Steel | material | Thickness | Diameter | Weight | Meters Per | |
(No./mm) | (No./mm) | (No./mm) | (mm) | (mm) | (kg/km) | Drum | ||
1×16+1×16 | 7/1.72 | 6/1.72 | 1/1.72 | XLPE | 1.2 | 12.5 | 121.9 | 250-4000m |
1×25+1×25 | 7/2.15 | 6/2.15 | 1/2.15 | 1.2 | 14.9 | 182.2 | 250-4000m | |
1×35+1×35 | 7/2.54 | 6/2.54 | 1/2.54 | 1.4 | 17.5 | 254.7 | 250-3500m | |
1×50+1×50 | 7/2.92 | 6/2.92 | 1/2.92 | 1.4 | 20.1 | 333.9 | 250-3000m | |
1×70+1×70 | 19/2.15 | 12/2.15 | 17/2.15 | 1.4 | 23.6 | 382.2 | 250-3000m | |
1×95+1×95 | 19/2.54 | 12/5.24 | 17/5.24 | 1.6 | 27.6 | 528.2 | 250-3000m | |
2×16+1×16 | 7/1.72 | 6/1.72 | 1/1.72 | (HDPE) | 1.2 | 14.2 | 187.6 | 250-4000m |
2×25+1×25 | 7/2.15 | 6/2.15 | 1/2.15 | 1.2 | 16.7 | 273.8 | 250-3500m | |
2×35+1×35 | 7/2.54 | 6/2.54 | 1/2.54 | 1.4 | 19.7 | 386.9 | 250-3500m | |
2×50+1×50 | 7/2.92 | 6/2.92 | 1/2.92 | 1.4 | 22.5 | 506 | 250-3000m | |
2×70+1×70 | 19/2.15 | 12/2.15 | 7/2.15 | 1.4 | 26.1 | 617.2 | 250-3000m | |
2×95+1×95 | 19/2.54 | 12/5.24 | 7/5.24 | 1.6 | 30.5 | 850.9 | 250-3000m | |
3×16+1×16 | 7/1.72 | 6/1.72 | 1/1.72 | 1.2 | 16.3 | 253.3 | 250-3500m | |
3×25+1×25 | 7/2.15 | 6/2.15 | 1/2.15 | 1.2 | 19.1 | 371.9 | 250-3500m | |
3×35+1×35 | 7/2.54 | 6/2.54 | 1/2.54 | 1.4 | 22.5 | 519.1 | 250-3000m | |
3×50+1×50 | 7/2.92 | 6/2.92 | 1/2.92 | 1.4 | 25.7 | 678.1 | 250-3000m | |
3×70+1×70 | 19/2.15 | 12/2.15 | 7/2.15 | 1.4 | 29.7 | 1024.3 | 250-3000m | |
2×95+1×95 | 19/2.54 | 12/2.54 | 7/2.54 | 1.6 | 34.6 | 1413.7 | 250-3000m |