PVC Insulated Swa Cable (VV32/VV22)
Product Detail
Basic Info
Extra Informatie.
Beschrijving
PVC Insulated Swa Cable (VV32/VV22)
Application:
With the characteristics of stable capability,advanced technology,broad material resources,low price, good flexible and easy to lay and maintain, the PVC Insulated and Sheathed Power Cable are suitable to be laid for distribution line with A.C.50HZ and rated voltage up to 6kV.
Property:
1.The long-time permissible working temperature of cable conductive core is not more than 70 °C.
2.During short circuit (max. permanent time is not more than 5 seconds), the max temperature of cable conductor is not more than 165°C.
3.The difference level of laying cable is not restricted.When laying the cable,ambient temperature is not lower than 0°C.
4.They have good chemical stability,and properties of acid resistance,alkali resistance,salt resistance,oil resistance,solvent resistance and flame resistance.rty
5.Light weight,good bending property and easy installation and maintenance.
Specification:
Standard:
IEC,BS,VDE,AS/NZS,ICEA,JIS and so on,designing and manufacturing special power cable according to the other standards required by the customer
1)600/1000V, Single Core, Circular Compacted Al or Cu/PVC/PVC Unarmoured or Armoured Power Cable
Cross Section of Conductor | No. of Wires | Thickness of Insulation | Unarmoured | Armoured | ||||||||
Thickness of Sheath | Overall Dia. | Approx.Net Weight | Thickness of Bedding | Thickness of Al Tape | Thickness of Sheath | Overall Dia. | Approx.Net Weight | |||||
Al Conductor | Cu Conductor | Al Conductor | Cu Conductor | |||||||||
mm2 | – | mm | mm | mm | kg/km | kg/km | mm | mm | mm | mm | kg/km | kg/km |
1.5 | 1 | 0.8 | 1.4 | 5.8 | – | 51 | – | – | – | – | – | – |
2.5 | 1 | 0.8 | 1.4 | 6.2 | – | 64 | – | – | – | – | – | – |
4 | 1 | 1 | 1.4 | 7.1 | – | 88 | – | – | – | – | – | – |
6 | 7 | 1 | 1.4 | 7.8 | 78 | 114 | – | – | – | – | – | – |
10 | 7 | 1 | 1.4 | 8.6 | 96 | 159 | 1 | 0.5 | 1.8 | 13.4 | 234 | 295 |
16 | 7 | 1 | 1.4 | 9.6 | 123 | 222 | 1 | 0.5 | 1.8 | 14.4 | 274 | 370 |
25 | 7 | 1.2 | 1.4 | 11.2 | 172 | 328 | 1 | 0.5 | 1.8 | 16 | 344 | 496 |
35 | 7 | 1.2 | 1.4 | 12.2 | 209 | 428 | 1 | 0.5 | 1.8 | 17 | 393 | 606 |
50 | 19 | 1.4 | 1.4 | 13.9 | 271 | 565 | 1 | 0.5 | 1.8 | 18.7 | 478 | 764 |
70 | 19 | 1.4 | 1.5 | 15.9 | 356 | 818 | 1 | 0.5 | 1.8 | 20.5 | 582 | 1020 |
95 | 19 | 1.6 | 1.5 | 18 | 471 | 1041 | 1 | 0.5 | 1.8 | 22.6 | 717 | 1291 |
120 | 37 | 1.6 | 1.6 | 19.6 | 563 | 1307 | 1 | 0.5 | 1.8 | 24 | 822 | 1545 |
150 | 37 | 1.8 | 1.6 | 21.3 | 684 | 1592 | 1 | 0.5 | 1.8 | 25.4 | 952 | 1857 |
185 | 37 | 2 | 1.7 | 23.9 | 840 | 1985 | 1 | 0.5 | 1.8 | 27.9 | 1136 | 2236 |
240 | 61 | 2.2 | 1.8 | 27 | 1071 | 2533 | 1 | 0.5 | 1.9 | 31 | 1404 | 2877 |
300 | 61 | 2.4 | 1.9 | 29.6 | 1317 | 3162 | 1.2 | 0.5 | 2.1 | 34.3 | 1722 | 3551 |
400 | 61 | 2.6 | 2 | 33.2 | 1666 | 4120 | 1.2 | 0.5 | 2.2 | 37.6 | 2114 | 4488 |
500 | 61 | 2.8 | 2.2 | 37.5 | 2089 | 5163 | 1.2 | 0.5 | 2.3 | 42.1 | 2592 | 5683 |
630 | 61 | 2.8 | 2.3 | 41.2 | 2581 | 6447 | 1.4 | 0.5 | 2.4 | 46.3 | 3184 | 7060 |
2)600/1000V, Multi Cores, Sectoral Compacted Al or Cu/PVC/PVC Unarmoured Power Cable
Number of Cores | Cross-Section of Conductor | No. Of Wires | Thickness of Insulation | Thickness of Sheath | Overall Diameter | Approx. Net Weight | |
Al Conductor | Cu Conductor | ||||||
– | mm2 | – | mm | mm | mm | kg/km | kg/km |
Three Cores | 3×35 | 16 | 1.2 | 1.8 | 21.9 | 601 | 1280 |
3×50 | 18 | 1.4 | 1.8 | 26.5 | 829 | 1732 | |
3×70 | 18 | 1.4 | 1.9 | 29.2 | 1067 | 2367 | |
3×95 | 36 | 1.6 | 2 | 32.9 | 1409 | 2317 | |
3×120 | 36 | 1.6 | 2.1 | 36.2 | 1705 | 3983 | |
3×150 | 36 | 1.8 | 2.2 | 38.8 | 2045 | 4872 | |
3×185 | 36 | 2 | 2.4 | 44.8 | 2596 | 6077 | |
3×240 | 60 | 2.2 | 2.6 | 51.5 | 3353 | 7953 | |
3×300 | 60 | 2.4 | 2.7 | 54.9 | 6069 | 9820 | |
Four Cores with Reduced Neutral | 3×35+16 | 16-7 | 1.2-1 | 1.8 | 25.5 | 764 | 1107 |
3×50+25 | 18-16 | 1.4-1.2 | 1.9 | 28.7 | 982 | 1410 | |
3×70+35 | 18-16 | 1.4-1.2 | 2.0 | 32 | 1278 | 1733 | |
3×95+50 | 36-18 | 1.6-1.4 | 2.2 | 37.8 | 1711 | 2656 | |
3×120+70 | 36-18 | 1.6-1.4 | 2.3 | 40.5 | 2065 | 3137 | |
3×150+70 | 36-18 | 1.8-1.4 | 2.4 | 44.8 | 2480 | 3660 | |
3×185+95 | 36-36 | 2-1.6 | 2.6 | 49.7 | 3086 | 4345 | |
3×240+120 | 60-36 | 2.2-1.6 | 2.8 | 56 | 3894 | 5441 | |
3×300+150 | 60-36 | 1.4-1.8 | 2.9 | 60.3 | 4834 | 6494 | |
Four Cores | 4×25 | 16 | 1.2 | 1.8 | 22.5 | 644 | 1286 |
4×35 | 16 | 1.2 | 1.8 | 24.6 | 799 | 1696 | |
4×50 | 18 | 1.4 | 1.8 | 28.6 | 1071 | 2275 | |
4×70 | 18 | 1.4 | 2 | 31.6 | 1387 | 3120 | |
4×95 | 36 | 1.6 | 2.1 | 35.9 | 1850 | 4262 | |
4×120 | 36 | 1.6 | 2.2 | 38.8 | 2209 | 5247 | |
4×150 | 36 | 1.8 | 2.3 | 43.1 | 2714 | 6483 | |
4×185 | 36 | 2 | 2.5 | 48.7 | 3403 | 8045 | |
4×240 | 60 | 2.2 | 2.7 | 53.6 | 4290 | 10422 | |
4×300 | 60 | 2.4 | 2.9 | 58.8 | 5302 | 12969 |
3)600/1000V, Multi Cores, Circular Compacted Al or Cu/PVC/PVC Unarmoured Power Cable
Number of Cores | Cross-Section of Conductor | No. Of Wires | Thickness of Insulation | Thickness of Sheath | Overall Diameter | Approx. Net Weight | ||
Al Conductor | Cu Conductor | |||||||
– | mm2 | – | mm | mm | mm | kg/km | kg/km | |
Three Cores | 3×10 | 7 | 1 | 1.8 | 16.6 | 281 | 465 | |
3×16 | 7 | 1 | 1.8 | 18.7 | 387 | 679 | ||
3×25 | 7 | 1.2 | 1.8 | 22.2 | 536 | 996 | ||
3×35 | 7 | 1.2 | 1.8 | 24.4 | 665 | 1311 | ||
3×50 | 19 | 1.4 | 1.9 | 28.1 | 863 | 1729 | ||
3×70 | 19 | 1.4 | 2 | 32.3 | 1153 | 2480 | ||
3×95 | 19 | 1.6 | 2.1 | 37.1 | 1563 | 3301 | ||
3×120 | 37 | 1.6 | 2.3 | 40.4 | 1850 | 4040 | ||
3×150 | 37 | 1.8 | 2.4 | 43.9 | 2258 | 5000 | ||
3×185 | 37 | 2 | 2.5 | 49.2 | 2819 | 6151 | ||
3×240 | 61 | 2.2 | 2.8 | 55.9 | 3577 | 8040 | ||
3×300 | 61 | 2.4 | 3 | 62.1 | 4413 | 9955 | ||
3×400 | 61 | 2.6 | 3.2 | 69.3 | 5512 | 12705 | ||
Four Cores | 4×10 | 7 | 1 | 1.8 | 18.1 | 343 | 589 | |
4×16 | 7 | 1 | 1.8 | 20.5 | 487 | 874 | ||
4×25 | 7 | 1.2 | 1.8 | 24.3 | 677 | 1291 | ||
4×35 | 7 | 1.2 | 1.8 | 26.8 | 821 | 1681 | ||
4×50 | 19 | 1.4 | 2 | 31.2 | 1118 | 2273 | ||
4×70 | 19 | 1.4 | 2.1 | 35.8 | 1494 | 3264 | ||
4×95 | 19 | 1.6 | 2.3 | 41.2 | 1993 | 4312 | ||
4×120 | 37 | 1.6 | 2.4 | 44.8 | 2370 | 5291 | ||
4×150 | 37 | 1.8 | 2.5 | 48.7 | 2959 | 6615 | ||
4×185 | 37 | 2 | 2.7 | 54.7 | 3601 | 8044 | ||
4×240 | 61 | 2.2 | 3 | 62.1 | 4596 | 10547 | ||
4×300 | 61 | 2.4 | 3.2 | 69.1 | 5614 | 13004 |
4)600/1000V, Multi Cores, Sectoral Compacted Al or Cu/PVC/PVC Armoured Power Cable
Cross Section of Conductor | No. of Wires | Thickness of Insulation | Thickness of Inner Sheath | Thickness of Steel Tape | No./Dia. Of Steel Wires | Thickness of Sheath | Overall Diameter | Approx. Net Weight | ||||||
STA | SWA | |||||||||||||
STA | SWA | STA | SWA | STA | SWA | Al Conductor | Cu Conductor | Al Conductor | Cu Conductor | |||||
mm2 | – | mm | mm | mm | No./mm | mm | mm | mm | mm | kg/km | kg/km | kg/km | kg/km | |
Three Cores | ||||||||||||||
3×35 | 16 | 1.2 | 1 | 0.2 | 38/1.6 | 1.8 | 1.9 | 24.7 | 28.2 | 912 | 1591 | 1447 | 2126 | |
3×50 | 18 | 1.4 | 1 | 0.2 | 46/1.6 | 1.9 | 2 | 29.3 | 32.8 | 1202 | 2105 | 1842 | 2745 | |
3×70 | 18 | 1.4 | 1.2 | 0.2 | 41/2.0 | 2.0 | 2.2 | 32.5 | 37.1 | 1520 | 2820 | 2475 | 3775 | |
3×95 | 36 | 1.6 | 1.2 | 0.5 | 46/2.0 | 2.1 | 2.3 | 36.5 | 40.8 | 2241 | 4049 | 2989 | 4797 | |
3×120 | 36 | 1.6 | 1.2 | 0.5 | 50/2.0 | 2.2 | 2.4 | 39.8 | 44.1 | 2617 | 4895 | 3435 | 5713 | |
3×150 | 36 | 1.8 | 1.2 | 0.5 | 43/2.5 | 2.3 | 2.5 | 42.4 | 47.8 | 3019 | 5846 | 4258 | 7085 | |
3×185 | 36 | 2 | 1.4 | 0.5 | 50/2.5 | 2.5 | 2.7 | 48.8 | 54.2 | 3783 | 7264 | 5219 | 8700 | |
3×240 | 60 | 2.2 | 1.6 | 0.5 | 58/2.5 | 2.8 | 2.9 | 56 | 61.3 | 4790 | 9390 | 6444 | 11044 | |
3×300 | 60 | 2.4 | 1.6 | 0.5 | 61/2.5 | 2.9 | 3.1 | 59.3 | 64.7 | 5594 | 11345 | 7458 | 13209 | |
Four Cores with Reduced Neutral | ||||||||||||||
3×35+16 | 16-7 | 1.2-1 | 1 | 0.2 | 43/1.6 | 1.9 | 2 | 28.5 | 31.3 | 1107 | 1528 | 1705 | 2469 | |
3×50+25 | 18-16 | 1.4-1.2 | 1.2 | 0.2 | 40/2.0 | 2.0 | 2.1 | 32.2 | 36.1 | 1410 | 2044 | 2326 | 3388 | |
3×70+35 | 18-16 | 1.4-1.2 | 1.2 | 0.2 | 44/2.0 | 2.0 | 2.2 | 35.2 | 39.3 | 1733 | 2801 | 2762 | 4285 | |
3×95+50 | 36-18 | 1.6-1.4 | 1.2 | 0.5 | 41/2.5 | 2.3 | 2.5 | 42.5 | 46.3 | 2656 | 3820 | 3816 | 5925 | |
3×120+70 | 36-18 | 1.6-1.4 | 1.4 | 0.5 | 45/2.5 | 2.4 | 2.6 | 45.6 | 49.4 | 3137 | 4777 | 4391 | 7103 | |
3×150+70 | 36-18 | 1.8-1.4 | 1.4 | 0.5 | 49/2.5 | 2.6 | 2.7 | 49.9 | 53.6 | 3660 | 5709 | 5043 | 8272 | |
3×185+95 | 36-36 | 2-1.6 | 1.4 | 0.5 | 55/2.5 | 2.6 | 2.9 | 54.5 | 58.5 | 3445 | 7171 | 5902 | 9987 | |
3×240+120 | 60-36 | 2.2-1.6 | 1.6 | 0.5 | 62/2.5 | 2.9 | 3.1 | 61.6 | 65.3 | 5441 | 9272 | 7174 | 12552 | |
3×300+150 | 60-36 | 1.4-1.8 | 1.6 | 0.5 | 67/2.5 | 3.8 | 3.2 | 65.9 | 69.6 | 6494 | 11546 | 8355 | 15067 | |
Four Cores | ||||||||||||||
4×25 | 16 | 1.2 | 1 | 0.2 | 38/1.6 | 1.8 | 1.9 | 25.3 | 28 | 934 | 1576 | 1450 | 2092 | |
4×35 | 16 | 1.2 | 1 | 0.2 | 41/1.6 | 1.8 | 1.9 | 27.4 | 30.2 | 1120 | 2017 | 1681 | 2578 | |
4×50 | 18 | 1.4 | 1 | 0.2 | 39/2.0 | 2 | 2.1 | 31.6 | 35.6 | 1454 | 2658 | 2336 | 3540 | |
4×70 | 18 | 1.4 | 1.2 | 0.5 | 43/2.0 | 2.1 | 2.2 | 36.3 | 39 | 2183 | 3916 | 2840 | 4573 | |
4×95 | 36 | 1.6 | 1.2 | 0.5 | 50/2.0 | 2.3 | 2.4 | 40.6 | 44.1 | 2748 | 5160 | 3545 | 5957 | |
4×120 | 36 | 1.6 | 1.4 | 0.5 | 42/2.5 | 2.4 | 2.5 | 43.9 | 47.2 | 3237 | 6214 | 4334 | 7372 | |
4×150 | 36 | 1.8 | 1.4 | 0.5 | 48/2.5 | 2.5 | 2.6 | 48.3 | 52 | 3853 | 7622 | 5148 | 8917 | |
4×185 | 36 | 2 | 1.6 | 0.5 | 54/2.5 | 2.7 | 2.8 | 54.3 | 57.6 | 4756 | 9323 | 6132 | 10774 | |
4×240 | 60 | 2.2 | 1.6 | 0.5 | 59/2.5 | 2.9 | 3 | 59.2 | 62.9 | 5774 | 11906 | 7374 | 13506 | |
4×300 | 60 | 2.4 | 1.6 | 0.5 | 65/2.5 | 3 | 3.2 | 64.3 | 68.1 | 6922 | 14589 | 8624 | 16291 |
5)600/1000V, Multi Cores, Circular Compacted Al or Cu/PVC/PVC Armoured Power Cable
Cross Section of Conductor | No. of Wires | Thickness of Insulation | Thickness of Inner Sheath | Thickness of Steel Tape | No./Dia. Of Steel Wires | Thickness of Sheath | Overall Diameter | Approx. Net Weight | |||||
STA | SWA | ||||||||||||
STA | SWA | STA | SWA | STA | SWA | Al Conductor | Cu Conductor | Al Conductor | Cu Conductor | ||||
mm2 | – | mm | mm | mm | No./mm | mm | mm | mm | mm | kg/km | kg/km | kg/km | kg/km |
Three Cores | |||||||||||||
3×10 | 7 | 1 | 1 | 0.2 | 35/1.25 | 1.8 | 1.8 | 19.4 | 21.5 | 494 | 679 | 988 | 1172 |
3×16 | 7 | 1 | 1 | 0.2 | 32/1.6 | 1.8 | 1.8 | 21.5 | 24.3 | 604 | 895 | 1051 | 1343 |
3×25 | 7 | 1.2 | 1 | 0.2 | 38/1.6 | 1.8 | 1.8 | 25 | 27.9 | 791 | 1252 | 1329 | 1790 |
3×35 | 7 | 1.2 | 1 | 0.2 | 42/1.6 | 1.8 | 1.9 | 27.2 | 30.2 | 950 | 1595 | 1551 | 2196 |
3×50 | 19 | 1.4 | 1.1 | 0.2 | 39/2.0 | 2 | 2.1 | 31.3 | 35.2 | 1213 | 2079 | 2128 | 2994 |
3×70 | 19 | 1.4 | 1.2 | 0.5 | 45/2.0 | 2.1 | 2.2 | 35.6 | 40.1 | 1567 | 2894 | 2678 | 4005 |
3×95 | 19 | 1.6 | 1.3 | 0.5 | 42/2.5 | 2.3 | 2.4 | 42 | 46.2 | 2449 | 4188 | 3689 | 5428 |
3×120 | 37 | 1.6 | 1.3 | 0.5 | 45/2.5 | 2.4 | 2.5 | 45.3 | 49.6 | 2823 | 5014 | 4174 | 6364 |
3×150 | 37 | 1.8 | 1.4 | 0.5 | 49/2.5 | 2.5 | 2.7 | 48.9 | 53.2 | 3327 | 6069 | 4795 | 7537 |
3×185 | 37 | 2 | 1.5 | 0.5 | 56/2.5 | 2.7 | 2.8 | 54.5 | 58.7 | 4038 | 7371 | 5686 | 9019 |
3×240 | 61 | 2.2 | 1.6 | 0.5 | 63/2.5 | 2.9 | 3.1 | 61.4 | 65.2 | 4994 | 9457 | 6862 | 11325 |
3×300 | 61 | 2.4 | 1.7 | 0.5 | 70/2.5 | 3.2 | 3.3 | 67.9 | 71.7 | 6022 | 11564 | 8101 | 13643 |
3×400 | 61 | 2.6 | 1.9 | 0.5 | 62/3.15 | 3.4 | 3.6 | 75.4 | 80.5 | 7350 | 14543 | 10535 | 17728 |
Four Cores | |||||||||||||
4×10 | 7 | 1 | 1 | 0.2 | 39/1.25 | 1.8 | 1.8 | 20.9 | 23 | 552 | 798 | 1073 | 1319 |
4×16 | 7 | 1 | 1 | 0.2 | 35/1.6 | 1.8 | 1.8 | 23.3 | 26.1 | 723 | 1110 | 1213 | 1601 |
4×25 | 7 | 1.2 | 1 | 0.2 | 42/1.6 | 1.8 | 1.9 | 27.2 | 30.2 | 959 | 1573 | 1559 | 2173 |
4×35 | 7 | 1.2 | 1 | 0.2 | 37/2.0 | 1.9 | 2 | 29.7 | 33.6 | 1140 | 2000 | 2006 | 2866 |
4×50 | 19 | 1.4 | 1.2 | 0.2 | 44/2.0 | 2.1 | 2.2 | 34.6 | 38.4 | 1524 | 2679 | 2541 | 3696 |
4×70 | 19 | 1.4 | 1.2 | 0.5 | 50/2.0 | 2.3 | 2.3 | 40.5 | 43.7 | 2338 | 4107 | 3187 | 4956 |
4×95 | 19 | 1.6 | 1.2 | 0.5 | 46/2.5 | 2.4 | 2.6 | 45.9 | 50.2 | 2955 | 5274 | 4325 | 6644 |
4×120 | 37 | 1.6 | 1.4 | 0.5 | 51/2.5 | 2.6 | 2.7 | 50 | 54.2 | 3466 | 6387 | 4568 | 7888 |
4×150 | 37 | 1.8 | 1.4 | 0.5 | 55/2.5 | 2.7 | 2.8 | 53.8 | 58.1 | 4144 | 7800 | 5772 | 9428 |
4×185 | 37 | 2 | 1.6 | 0.5 | 62/2.5 | 2.9 | 3 | 60.2 | 64.5 | 4987 | 9430 | 6822 | 11266 |
4×240 | 61 | 2.2 | 1.6 | 0.5 | 70/2.5 | 3.1 | 3.3 | 67.7 | 71.5 | 6161 | 12111 | 8233 | 14184 |
4×300 | 61 | 2.4 | 1.6 | 0.5 | 61/3.15 | 3.4 | 3.5 | 74.7 | 78.8 | 7346 | 14735 | 10305 | 17694 |
- Next: Hot Selling Product ACSR Aluminum Conductor (LJ/LGJ)
- Previous: High Quality XLPE Insulated ABC Cable
Contact us
Soortgelijk of gerelateerd
- No related articles