Yaky, de Kabel van de Macht, 0.6/1 Kv, Vlam - de Klasse C Al/PVC/PVC van de vertrager (CEI 60502-1)
Product Detail
Basic Info
Extra Informatie.
Beschrijving
YAKY, Power Cable, 0.6/1 KV, Flame Retardant Class C AL/PVC/PVC (IEC 60502-1)
Structure:
1 | Aluminium conductor, round solid (RE), sector-shaped solid (SE), round stranded (RM), resp. sector-shaped solid (SM)
2 | Core insulation (PVC)
3 | Inner covering (EPDM or plastic tape)
4 | Sheath (YAKY – PVC black, UV-restistant)
Application:
The cables are intended for distribution of electrical energy. Power distribution cables in power stations, industrial installations and switchgears, as well as in local mains. For fi xed installation underground, in interior premises, cable ducts, in the open air, in water – as permitted by the local building regulations – if no risk of any mechanical damage is to be expected.
Rated voltage: 0.6/1 KV
Test voltage: 3.5 kV/50 Hz
Temperature range:
laying temperature : min. -5ºC
operating temperature: -50ºC-+70ºC
conductor temperature : max. +70ºC
short-circult temperature: max. +160ºC/5 s
Bending radius (min.):
15 x ? of cable (single core)
12 x ? of cable (multi-core)
Core identification:
HD 308 S2
Fire properties:
flame retardant: EN 60332-1-2
Number of cores x nominal cross section | Max. conductor resistance | Current rating in the ground | Current rating in the air | Outer diameter | Total weight |
(mm²) | (Ω/km) | (A) | (A) | (mm) | (kg/km) |
E-XAYY | |||||
4 x 16 RE | 1.910 | 81 | 61 | 20.9 | 595 |
5 x 16 RE | 1.910 | 81 | 61 | 22.3 | 705 |
1 x 25 RE | 1.200 | 160 | 110 | 11.6 | 195 |
4 x 25 RE | 1.2 | 102 | 82 | 24.5 | 885 |
5 x 25 RE | 1.2 | 102 | 82 | 26.4 | 1,110 |
1 x 35 RE | 0.868 | 193 | 135 | 12.6 | 235 |
4 x 35 RE | 0.868 | 123 | 100 | 26.9 | 1,095 |
5 x 35 RM | 0.868 | 123 | 100 | 31.3 | 1,380 |
5 x 35 SM | 0.868 | 123 | 100 | 28.3 | 1,020 |
1 x 50 RM | 0.641 | 230 | 166 | 14.3 | 305 |
4 x 50 SE | 0.641 | 144 | 119 | 29.5 | 1,060 |
4x 50 SM | 0.641 | 144 | 119 | 28.8 | 1,150 |
5 x 50 SM | 0.641 | 144 | 119 | 34.2 | 1,380 |
1 x 70 RM | 0.443 | 283 | 210 | 16.1 | 390 |
4 x 70 SE | 0.443 | 179 | 152 | 30.5 | 1,400 |
4 x 70 SM | 0.443 | 179 | 152 | 32.5 | 1,400 |
5 x 70 SM | 0.443 | 179 | 152 | 39.2 | 1,790 |
1 x 95 RM | 0.32 | 340 | 259 | 18.4 | 505 |
4 x 95 SE | 0.32 | 215 | 186 | 35.1 | 1,810 |
4 x 95 SM | 0.32 | 215 | 186 | 37.4 | 1,830 |
5 x 95 SM | 0.32 | 215 | 186 | 45.6 | 2,350 |
1 x 120 RM | 0.253 | 389 | 302 | 20 | 590 |
3 x 120 + 70 SM/RM | 0.253 | 245 | 216 | 41 | 2,050 |
4 x 120 SE | 0.253 | 245 | 216 | 38.5 | 2,160 |
4 x 120 SM | 0.253 | 245 | 216 | 41 | 2,320 |
5 x 120 SM | 0.253 | 245 | 216 | 49.4 | 2,830 |
1 x 150 RM | 0.206 | 436 | 345 | 21.8 | 730 |
3 x 150 + 70 SM/RM | 0.206/0.443 | 275 | 246 | 45.5 | 2,380 |
4 x 150 SE | 0.206 | 275 | 246 | 42.5 | 2,540 |
4 x 150 SM | 0.206 | 275 | 246 | 45.5 | 2,670 |
5 x 150 SM | 0.206 | 275 | 246 | 55 | 3,450 |
1 x 185 RM | 0.164 | 496 | 401 | 24.3 | 890 |
3 x 185 + 95 SM/RM | 0.164/0.320 | 313 | 285 | 50.4 | 2,990 |
4 x 185 SM | 0.164 | 313 | 285 | 50.4 | 3,330 |
5 x 185 SM | 0.164 | 313 | 285 | 61.6 | 4,260 |
1 x 240 RM | 0.125 | 578 | 479 | 27.2 | 1,160 |
3 x 240 + 120 SM/RM | 0.125/0.253 | 364 | 338 | 57.1 | 3,810 |
4 x 240 SM | 0.125 | 364 | 338 | 57.1 | 4,520 |
5 x 240 SM | 0.125 | 364 | 338 | 69.3 | 5,390 |
1 x 300 RM | 0.1 | 656 | 555 | 30.3 | 1,390 |
1 x 400 RM | 0.078 | 756 | 653 | 35.5 | 1,770 |
1 x 500 RM | 0.061 | 873 | 772 | 37.6 | 2,160 |
1 x 630 RM | 0.047 | 1011 | 915 | 42.6 | 2,890 |
1 x 630 RM + 2 x 2.5 RE2) | 0.047 | 1011 | 915 | 42.6 | 2,970 |
- Next: Al/PVC/Sta/PVC, 0.6/1 Kv, Steel Tape Armor Power Cable (IEC 60502-1)
- Previous: Yslcy, Control Cable, 300/500 V, Flexible Cu/PVC/Tcwb/PVC (VDE 0281-13)
Contact us
Soortgelijk of gerelateerd
- No related articles